Rapid and sensitive determination of Se and heavy metals in foods using electrothermal vaporization inductively coupled plasma mass spectrometry with a novel transportation system

采用新型传输系统电热汽化电感耦合等离子体质谱法快速灵敏地测定食品中的硒和重金属

阅读:9
作者:Guanyu Lan, Xue Li, Jijun Yao, Xiaofeng Yu, Qinghai Liu, Cheng Qiu, Xuefei Mao

Abstract

Rapid, sensitive and simultaneous determination of trace multi-elements in various plant food samples such as grain, oilseed, vegetable and tea is always a challenge thus far. In this work, a rapid determination method for Se, Cd, As and Pb in food samples by inductively coupled plasma mass spectrometry (ICP-MS) using slurry sampling electrothermal vaporization (SS-ETV) was developed. To improve the analytical sensitivity and precision as well as eliminate the memory effect, a gas turbulator line and signal delay device (SDD) were for the first time designed for the graphite furnace (GF) ETV coupled with ICP-MS. The signal acquisition parameters of ICP-MS, ashing and vaporization conditions, and the flow rates of carrier gas and gas turbulator were investigated for Se, Cd, As and Pb in food samples. Under the optimized conditions, the limits of determination (LODs) for Se, Cd, As and Pb were 0.5 ng g-1, 0.3 ng g-1, 0.3 ng g-1 and 0.6 ng g-1, respectively; the limits of quantification (LOQs) for Se, Cd, As and Pb were 1.7 ng g-1, 1.0 ng g-1, 1.0 ng g-1 and 1.9 ng g-1, respectively; linearity (R2) in the range of 1 to 4,000 ng g-1 was >0.999 using the standard addition method. This method was used to analyze 5 CRMs including rice, tea and soybeans, and the concentrations detected by this method were within the range of the certified values. The recoveries of Se, Cd, As and Pb in plant food matrices including grain, oilseed, celery, spinach, carrot and tea samples were 86-118% compared to the microwave digestion ICP-MS method; and the relative standard deviations (RSDs) were 1.2-8.9% for real food sample analysis, proving a good precision and accuracy for the simultaneous determination of multi-elements. The analysis time was less than 3 min, slurry preparation time < 5 min without sample digestion process. The proposed direct slurry sampling ICP-MS method is thus suitable for rapid and sensitive determination of Se, Cd, As and Pb in food samples with advantages such as simplicity, green and safety, as well as with a promising application potential in detecting more elements to protect food safety and human health.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。