Point-of-Care Bilirubin Testing in Neonates: Comparative Performance of Blood Gas Analysis and Transcutaneous Bilirubinometry

新生儿床旁胆红素检测:血气分析与经皮胆红素测定法的性能比较

阅读:1

Abstract

Background: Neonatal jaundice is a common condition with potentially severe complications such as bilirubin-induced neurological dysfunction and kernicterus. While serum bilirubin (SBR) remains the standard laboratory measurement, point-of-care methods, such as transcutaneous bilirubinometry (TcB) and blood gas analysers (BGAs), offer rapid, less invasive alternatives. Direct comparisons of their diagnostic accuracy remain limited. Objective: The aim of this study was to assess and compare diagnostic accuracy and clinical utility of TcB and BGA against SBR in neonatal hyperbilirubinaemia screening. Methods: This retrospective study included neonates (n = 221) with concurrent SBR, BGA, and TcB measurements (n = 333). Assessment was via Passing-Bablok regression, Bland-Altman analysis, and Spearman correlation. Diagnostic performance was evaluated against jaundice thresholds in phototherapy charts (≥95th percentile threshold). Subgroup analyses considered phototherapy status, haemoglobin concentration, and Fitzpatrick skin type. Results: BGA showed stronger agreement with SBR (R(2) = 0.88) than TcB (R(2) = 0.43). BGA remained accurate regardless of phototherapy or haemoglobin levels. TcB accuracy declined post-phototherapy with reduced predictive value in darker-skinned neonates (Fitzpatrick III-VI) and increased false discovery rates. Both methods demonstrated low sensitivity (45.8%) but high specificity (>95%) and negative predictive value (~91%) for clinically significant hyperbilirubinaemia. BGA had a higher diagnostic odds ratio (47.5) than TcB (19.3). When individual patient sequential SBR and BGA measurements were compared for jaundice tracking (n = 175), there was high correlation, (r = 0.971) with no statistical differences, and 50% of measurements achieving agreement within 10 μmol/L. Conclusions: BGA is a more reliable alternative to SBR than TcB, particularly in time-critical or resource-limited settings. While TcB remains a non-invasive screening tool, limited accuracy post-phototherapy and with darker skinned neonates indicate confirmatory SBR testing. These findings support the selective and context-aware use of BGA and TcB to optimise neonatal hyperbilirubinaemia management and reduce interventions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。