Combining National Early Warning Score With Soluble Urokinase Plasminogen Activator Receptor (suPAR) Improves Risk Prediction in Acute Medical Patients: A Registry-Based Cohort Study

将国家早期预警评分与可溶性尿激酶型纤溶酶原激活物受体 (suPAR) 相结合可提高急性内科患者的风险预测:一项基于注册登记的队列研究

阅读:1

Abstract

OBJECTIVES: Soluble urokinase plasminogen activator receptor is a prognostic biomarker associated with critical illness, disease progression, and risk of mortality. We aimed to evaluate whether soluble urokinase plasminogen activator receptor adds prognostic value to a vital sign-based score for clinical monitoring of patient risk (National Early Warning Score) in acute medical patients. DESIGN: Registry-based observational cohort study of consecutively admitted acute medical patients. SETTING: The Acute Medical Unit, Copenhagen University Hospital Amager and Hvidovre, Hvidovre, Denmark. PATIENTS: Acute medical patients admitted between November 18, 2013, and September 30, 2015. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Of 17,312 included patients, admission National Early Warning Score was available for 16,244 (93.8%). During follow-up, 587 patients (3.4%) died in-hospital, 859 (5.0%) within 30 days, and 1,367 (7.9%) within 90 days. High soluble urokinase plasminogen activator receptor was significantly associated with in-hospital-, 30-day-, and 90-day mortality within all National Early Warning Score groups, in particular in patients with a low National Early Warning Score; for 30-day mortality, mortality rate ratios ranged from 3.45 (95% CI, 2.91-4.10) for patients with National Early Warning Score 0-1, to 1.86 (95% CI, 1.47-2.34) for patients with National Early Warning Score greater than or equal to 9 for every doubling in soluble urokinase plasminogen activator receptor (log2-transformed). Combining National Early Warning Score, age, and sex with soluble urokinase plasminogen activator receptor improved prediction of in-hospital-, 30-day-, and 90-day mortality, increasing the area under the curve (95% CI) for 30-day mortality from 0.86 (0.85-0.87) to 0.90 (0.89-0.91), p value of less than 0.0001, with a negative predictive value of 99.0%. CONCLUSIONS: The addition of soluble urokinase plasminogen activator receptor to National Early Warning Score significantly improved risk prediction of both low- and high-risk acute medical patients. Patients with low National Early Warning Score but elevated soluble urokinase plasminogen activator receptor had mortality risks comparable to that of patients with higher National Early Warning Score.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。