Ultrasonography for confirmation of gastric tube placement

超声检查用于确认胃管位置

阅读:1

Abstract

BACKGROUND: Gastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access. OBJECTIVES: To assess the diagnostic accuracy of ultrasound alone or in combination with other methods for gastric tube placement confirmation in children and adults. SEARCH METHODS: This systematic review is an update of a previously published Cochrane review. For this update, we searched the Cochrane Library (2021, Issue 6), MEDLINE (to April 2023), Embase (to April 2023), five other databases (to July 2021), and reference lists of articles, and contacted study authors. SELECTION CRITERIA: We included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies and case-control studies. We excluded case series or case reports. We excluded studies if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed the methodological quality and extracted data from each of the included studies. We contacted the authors of the included studies to obtain missing data. There were sparse data for specificity. Therefore, we performed a meta-analysis of only sensitivity using a univariate random-effects logistic regression model to combine data from studies that used the same method and echo window. MAIN RESULTS: We identified 12 new studies in addition to 10 studies included in the earlier version of this review, totalling 1939 participants and 1944 tube insertions. Overall, we judged the risk of bias in the included studies as low or unclear. No study was at low risk of bias or low concern for applicability in every QUADAS-2 domain. There were limited data (152 participants) for misplacement detection (specificity) due to the low incidence of misplacement. The summary sensitivity of ultrasound on neck and abdomen echo windows were 0.96 (95% confidence interval (CI) 0.92 to 0.98; moderate-certainty evidence) for air injection and 0.98 (95% CI 0.83 to 1.00; moderate-certainty evidence) for saline injection. The summary sensitivity of ultrasound on abdomen echo window was 0.96 (95% CI 0.65 to 1.00; very low-certainty evidence) for air injection and 0.97 (95% CI 0.95 to 0.99; moderate-certainty evidence) for procedures without injection. The certainty of evidence for specificity across all methods was very low due to the very small sample size. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (8 studies, 552 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide CIs. For studies of ultrasound alone (9 studies, 782 participants), sensitivity estimates ranged from 0.77 to 0.98 and specificity estimates were 1.00 with wide CIs or not estimable due to no occurrence of misplacement. AUTHORS' CONCLUSIONS: Of 22 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。