513 Towards Obtaining One Billion Recordings Per Cubic Millimeter for the Validation of Focused Ultrasound Transducers: How Can Robust Systems Help With Translational Activities?

513 为验证聚焦超声换能器,实现每立方毫米十亿次记录的目标:稳健的系统如何帮助转化活动?

阅读:2

Abstract

OBJECTIVES/GOALS: The first aim was to construct a controlled and high resolution FUS water tank characterization system with 1 micron step-sizes. The second aim was to create two unique standardized protocols for mapping the generated acoustic field from FUS transducers; protocol one maps the full 3D field while protocol two rapidly detects changes to the original plot. METHODS/STUDY POPULATION: To accomplish aim one, the focused ultrasound mapping platform was constructed with a water conditioning unit for water degassing and temperature control, a three-axis stage with 1 micron step-size capabilities, and a data plotting software. To measure the outcomes of aim one, the water temperature was monitored, and axis step sizes were measured through ten independent axis translation recordings. To accomplish aim two, FUS acquisitions were executed at different resolutions. For FUS localization at the cellular level, a 1-5 micron step size is required. Once the initial scan was performed, duplicate scans were executed to detect inherent perturbations or errors in the system. Once calculated, the best methods of detecting true changes to FUS signals are proposed. RESULTS/ANTICIPATED RESULTS: The FUS characterization system maintained water temperature and performed 1 micron step-sizes. While pre-existing platforms have demonstrated a resolution of one thousand recordings per cubic millimeter, the proposed system (time and computing power willing) can record one billion recordings per cubic millimeter. In practice, a resolution of 20 micron was sufficient for non-cellular level FUS characterizations. Successive 2D scans were reliably stacked to form a 3D rendering of the generated acoustic field with the average focal point intensity yielding a 1% coefficient of variation between identical scans. This inherent variation can be used as the threshold of significance for true change detection; to rapidly detect changes to the FUS signal, sampling can be performed at regions of high baseline values. DISCUSSION/SIGNIFICANCE: Focused ultrasound medical devices are gaining popularity for treatments including tumor ablation, neuromodulation, and drug delivery; however, the field lacks a standardized method to characterize these FUS transducers. The presented platform and protocols enable a rigorous and high quality translation through verification and validation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。