Surgical Explantation of a Fenestrated Endovascular Abdominal Aortic Aneurysm Repair Device Complicated by Aorto-Enteric Fistula

腹主动脉瘤腔内修复装置开窗术后并发主动脉肠瘘的手术取出

阅读:2

Abstract

INTRODUCTION: Alarming outcomes have been reported following infected endovascular aortic aneurysm repair (EVAR) device explantation. Infected fenestrated EVAR (FEVAR) exposes patients to even worse procedural risks. REPORT: A 67 year old man with a prior history of FEVAR presented with impaired general condition, abdominal and back pain, and increased C reactive protein. Computed tomography angiography revealed a collection around the aortic graft bifurcation and (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) revealed increased FDG uptake at this level, confirmed by labelled white blood cells, all favouring graft infection. A thoracophrenolumbotomy was performed and revealed an aorto-enteric fistula which was treated by small bowel resection. The left renal artery was transected at the distal end of the bridging stent and a thoracorenal bypass was performed. The thoracic aorta was cross clamped above the coeliac trunk for complete graft excision. Meanwhile, the right kidney was perfused with 4°C Ringer lactate solution. In situ reconstruction was accomplished with a bifurcated antimicrobial graft sutured below the superior mesenteric artery with re-implantation of the right renal artery. The patient was left with a laparostomy for definitive abdominal closure, restoration of the digestive tract, and omental wrap 72 hours later. Broad spectrum antibiotic therapy was initiated peri-operatively and reduced to sulfamethoxazole/trimethoprim for a total duration of six weeks after one sample was positive for Moraxella osloensis. Eleven months later, the patient was free from re-infection, with no fever or inflammatory syndrome. DISCUSSION: Total explantation of stent grafts with tissue debridement and post-operative antibiotic therapy is the gold standard when dealing with infected EVAR. As with type IV thoraco-abdominal aneurysm open repair, FEVAR device explantation requires additional protective measures to prevent visceral ischaemia and renal impairment. In agreement with the European Society for Vascular Surgery guidelines, such patients should be referred to dedicated vascular centres with expertise in surgical repair, anaesthetics, and post-operative intensive care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。