Identification of geometric and mechanical factors predictive of bird-beak configuration in thoracic endovascular aortic repair using computational models of stent graft deployment

利用支架移植物部署的计算模型,识别预测胸主动脉腔内修复术中“鸟嘴”构型的几何和力学因素。

阅读:2

Abstract

OBJECTIVE: Formation of a bird-beak configuration in thoracic endovascular aortic repair (TEVAR) has been shown to be influenced by various factors. However, the main cause of bird-beak formation remains poorly understood. The hypothesis has been that the geometric and mechanical properties of both the aorta and the stent graft contribute to the formation and extent of a bird-beak configuration. The goal of the present study was to use parameter-based computational simulations of TEVAR to predict for bird-beak formation and identify its most significant contributing factors. METHODS: In the present study, we considered five parameters for the computational simulations of TEVAR, including aortic curvature, aortic arch angle, age as a surrogate for thoracic aortic tissue properties, TEVAR landing zone, and stent graft oversizing. Using an experimental design approach, computational models for 160 TEVAR scenarios were developed by varying the values of the simulation parameters within clinically relevant ranges. The bird-beak length and angle were used as metrics to evaluate the simulation results. Statistical analysis of the simulation data using a random forest model was conducted to identify significant parameters and interactions. RESULTS: The mean ± standard deviation of the bird-beak length and angle across 160 simulations were 4.32 ± 4.87 mm and 9.16° ± 12.21°, respectively. The largest mean bird-beak length and angle were found in the most distal location in zone 0 (10.04 mm) and zone 2 (21.48°), respectively. An inverse correlation was found between the aortic arch angle and the bird-beak length and angle. In ∼75% of the scenarios, increased stent graft oversizing either fully resolved the presence of the bird-beak configuration or had reduced its size. In the remaining 25%, oversizing minimally changed the bird-beak length and enlarged the bird-beak angle, which mainly occurred in cases with a smaller aortic arch angle and landing zones near the arch apex. This was justified by the mechanism of stent graft bending in the arch angulation. The aortic curvature and tissue properties were shown to be statistically insignificant in relation to bird-beak formation. CONCLUSIONS: Significant parameters predictive of a bird-beak configuration in TEVAR were identified, and the trends in which each parameter influenced the bird-beak size were determined. The findings from the present study can inform the surgical planning and device selection process with the goal of minimizing bird-beak formation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。