Wear Rates of XLPE Nearly 50% Lower Than Previously Thought After Adjusting for Initial Creep: An RCT Comparing 4 Bearing Combinations

校正初始蠕变后,交联聚乙烯(XLPE)的磨损率比之前认为的低近50%:一项比较4种轴承组合的随机对照试验

阅读:1

Abstract

BACKGROUND: The ideal bearing combination for total hip arthroplasty (THA) remains debatable. Highly cross-linked polyethylene (XLPE) is widely used, but long-term wear rates are not fully known, nor is how much the initial "creep," if any, affects overall wear. Additionally, the use of oxidized zirconium (OxZir) is purported to lower polyethylene wear rates, but this has not been proven. We present the 10-year data of a cohort of patients who underwent THA. Patients were prospectively randomized to 1 of 4 bearing combinations: a conventional ultra-high molecular weight polyethylene (UHMWPE) or XLPE acetabular liner coupled with either a cobalt-chromium (CoCr) or OxZir femoral head. The aims of the study were to (1) assess the extent to which creep affected overall wear rates and (2) assess wear rates between OxZir and CoCr with polyethylene. METHODS: A total of 92 hips (92 patients) between the ages of 22 and 65 years (mean, 52.2 ± 9.3 years) were randomized to 4 groups. At 10 years, 70 (76%) of the hips were available for analysis; patients who had undergone revision, had died, or were lost to follow-up were excluded from final analysis. Radiographic analysis was performed using a validated digital assessment program to determine linear, volumetric, and directional wear of the polyethylene for all 4 bearing couples. Radiographic assessments were performed immediately postoperatively, at 6 and 12 weeks, and then annually for a minimum of 10 years. RESULTS: XLPE had significantly lower wear rates than UHMWPE. Once creep was eliminated, annual and overall wear rates were nearly 50% lower than have been previously reported. This was proportionally more important in the XLPE group than in the UHMWPE group. There was a nonsignificant trend toward a lower wear rate with OxZir heads. CONCLUSIONS: Creep plays a notably more important role than first thought. Once creep was eliminated, the overall wear rate was even lower than previously assumed. This has important implications for the overall survivorship of hip arthroplasty implants. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。