Can SBAR be implemented with high fidelity and does it improve communication between healthcare workers? A systematic review

SBAR 能否高保真地实施,并能改善医护人员之间的沟通?一项系统性综述

阅读:2

Abstract

OBJECTIVE: To characterise the extent to which health professionals perform SBAR (situation, background, assessment, recommendation) as intended (ie, with high fidelity) and the extent to which its use improves communication clarity or other quality measures. DATA SOURCES: Medline, Healthstar, PsycINFO, Embase and CINAHL to October 2020 and handsearching selected journals. STUDY SELECTION AND OUTCOME MEASURES: Eligible studies consisted of controlled trials and time series, including simple before-after design, assessing SBAR implementation fidelity or the effects of SBAR on communication clarity or other quality measures (eg, safety climate, patient outcomes). DATA EXTRACTION AND SYNTHESIS: Two reviewers independently abstracted data according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses on study features, intervention details and study outcomes. We characterised the magnitude of improvement in outcomes as small (<20% relative increase), moderate (20%-40%) or large (>40%). RESULTS: Twenty-eight studies (3 randomised controlled trials, 6 controlled before-after studies, and 19 uncontrolled before-after studies) met inclusion criteria. Of the nine studies assessing fidelity of SBAR use, four occurred in classroom settings and three of these studies reported large improvements. The five studies assessing fidelity in clinical settings reported small to moderate effects. Among eight studies measuring communication clarity, only three reported large improvements and two of these occurred in classroom settings. Among the 17 studies reporting impacts on quality measures beyond communication, over half reported moderate to large improvements. These improvements tended to involve measures of teamwork and culture. Improvements in patient outcomes occurred only with intensive multifaceted interventions (eg, early warning scores and rapid response systems). CONCLUSIONS: High fidelity uptake of SBAR and improvements in communication clarity occurred predominantly in classroom studies. Studies in clinical settings achieving impacts beyond communication typically involved broader, multifaceted interventions. Future efforts to improve communication using SBAR should first confirm high fidelity uptake in clinical settings rather than assuming this has occurred. PROSPERO REGISTRATION NUMBER: CRD42018111377.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。