Validation of the only commercially available immunoassay for synthetic cathinones in urine: Randox Drugs of Abuse V Biochip Array Technology

验证唯一可用于尿液合成卡西酮的商业化免疫测定法:Randox 药物滥用 V 生物芯片阵列技术

阅读:6
作者:Kayla N Ellefsen, Sébastien Anizan, Marisol S Castaneto, Nathalie A Desrosiers, Thomas M Martin, Kevin L Klette, Marilyn A Huestis

Abstract

Deterrence of synthetic cathinone abuse is hampered by the lack of a high-throughput immunoassay screen. The Randox Drugs of Abuse V (DOA-V) Biochip Array Technology contains two synthetic cathinone antibodies: Bath Salt I (BSI) targets mephedrone/methcathinone and Bath Salt II (BSII) targets 3',4'-methylenedioxypyrovalerone (MDPV)/3',4'-methylenedioxy-α-pyrrolidinobutiophenone (MDPBP). We evaluated DOA-V synthetic cathinones performance and conducted a full validation on the original assay with calibrators reconstituted in water, and the new assay with calibrators prepared in lyophilized urine; both utilized the same antibodies and were run on the fully automated Evidence® Analyzer. We screened 20 017 authentic military urine specimens and confirmed positives by liquid chromatography-tandem mass spectrometry (LC-MS/MS) for 28 synthetic cathinones. Limits of detection (LOD) for the original and new assays were 0.35 and 0.18 (BSI), and 8.5 and 9.2 µg/L (BSII), respectively. Linearity was acceptable (R(2) >0.98); however, a large negative bias was observed with in-house prepared calibrators. Intra-assay imprecision was <20% BSI-II, while inter-assay imprecision was 18-42% BSI and <22% BSII. Precision was acceptable for Randox controls. Cross-reactivities of many additional synthetic cathinones were determined. Authentic drug-free negative urine pH <4 produced false positive results for BSI (6.3 µg/L) and BSII (473 µg/L). Oxidizing agents reduced BSI and increased BSII results. Sensitivity, specificity, and efficiency of 100%, 52.1%, and 53.0% were obtained at manufacturer's proposed cut-offs (BSI 5 µg/L, BSII 30 µg/L). Performance improved if cut-off concentrations increased (BSI 7.5 µg/L, BSII 40 µg/L); however, there were limited confirmed positive specimens. Currently, this is the first and only fully validated immunoassay for preliminary detection of synthetic cathinones in urine. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。