The Role of Rapid Curing on the Interrelationship Between Temperature Rise, Light Transmission, and Polymerisation Kinetics of Bulk-Fill Composites

快速固化对本体填充复合材料温度升高、透光率和聚合动力学之间相互关系的影响

阅读:3

Abstract

The first seconds of light curing are crucial for the development of most properties of dental composites, especially for the 3s high-irradiance curing. This study investigated the influence of rapid high-irradiance curing on temporal development of temperature, transmittance and conversion of bulk-fill composites. Four materials were tested: Filtek One (FO), Tetric PowerFill (PFill), Tetric PowerFlow (PFlow) and SDR flow+ (SDR+) and cured with three curing units (LCU): Valo Cordles, Bluephase PowerCure and Translux Wave in 3s (3 W/cm(2)), 10s (1 W/cm(2)) and 20s (1 W/cm(2)) curing protocols. Light transmittance was measured at 2 and 4 mm, while temperature rise and polymerisation kinetics were evaluated at 4 mm depth during 5 min. Both light transmittance and temperature rise were greatest for SDR+ > PFlow > PFill > FO. The 20s curing protocol resulted in the highest degree of conversion (DC) for all materials and LCUs, but also contributed to the greatest temperature rise. Rapid curing with the 3s protocol caused the lowest temperature rise and the shortest time to reach maximum temperature. The polymerisation and temperature kinetics were strongly dependent on the material. The DC of PFill was statistically similar for 3s, 10s or 20s curing with BPC. Rapid curing is only recommended for materials developed for this purpose.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。