Ultra-low-dose hepatic computed tomography with a novel real-time deep learning-based noise reduction algorithm: a prospective cross-sectional analysis of image quality and lesion detection

采用新型实时深度学习降噪算法的超低剂量肝脏计算机断层扫描:图像质量和病灶检测的前瞻性横断面分析

阅读:1

Abstract

BACKGROUND: Contrast-enhanced computed tomography (CT) is essential for tumor assessment, but the detection of low-contrast liver lesions remains challenging. Reducing the radiation dose increases image noise, compromising image quality and diagnostic accuracy. Iterative reconstruction (IR) algorithms can reduce noise; however, they can also alter image texture and limit lesion detection. Deep-learning image reconstruction (DLIR) represents a promising alternative, but its efficacy in ultra-low-dose (ULD) hepatic CT for detecting small, low-contrast lesions remains underexplored. Thus, this study aimed to evaluate a novel real-time DLIR algorithm in ULD hepatic CT, focusing on image quality and lesion detection. METHODS: In total, 65 patients with hepatic lesions underwent both standard-dose and ULD abdominal CT scans during the portal venous phase. The standard-dose protocol (group A) used 120 kV with a signal-to-noise ratio (SNR) of 1.0, and the images were reconstructed using 50% IR. The ULD protocol (group B) used 120 kV with an SNR of 0.5, and the images were reconstructed using 50% IR and 50% DLIR (groups B1 and B2, respectively). The quantitative and qualitative image quality parameters were assessed. The lesion detection rates were evaluated by lesion type and size using the metrics of detection rate, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). RESULTS: Group B showed a 73.3% reduction in the radiation dose compared to group A (1.5±0.8 vs. 6.9±2.0 mSv, P<0.001). Image noise differed significantly across the protocols: group B1 had the highest noise [10.05±2.94 Hounsfield units (HU)], followed by groups A (8.29±2.82 HU) and B2 (8.04±2.71 HU; all pairwise P<0.05 except group A vs. group B2: P=0.625). The CT values and contrast-to-noise ratios (CNRs) were comparable between groups B2 and A (all P>0.05), while group B2 had a 29.9-42.2% higher CNR than group B1 (all P<0.001). The qualitative assessments confirmed that the image quality and diagnostic acceptability of groups B2 (100%) and A (all P>0.05) were comparable, while the images of group B1 were diagnostically unacceptable (all scores <3). Overall, lesion detection was comparable in groups B2 (90.5%, 133/147) and A (98.0%, 144/147; P>0.05). However, group B2 had a significantly lower detection rate for small lesions (<0.5 cm: 77.8%, 42/54) compared to group A (P<0.05), but outperformed group B1 (57.4%, 31/54; P<0.05). Group B2 also had a significantly improved lesion detection rate and sensitivity for low-contrast lesions (87.2%, 95/109) compared to group B1 (75.2%, 82/109; P<0.05). The novel DLIR algorithm achieved a reconstruction speed of 60 images per second (ips), which was significantly faster than that of other DLIR approaches, while maintaining comparable performance to the IR algorithm. CONCLUSIONS: The combination of tube current reduction with a novel real-time DLIR algorithm enabled ULD abdominal CT to achieve a 73.3% reduction in the radiation dose while maintaining image quality and diagnostic performance for detecting hepatic lesions larger than 0.5 cm.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。