Rapid Electrochemical Profiling of Fecal Short-Chain Fatty Acids Using Esterification/Dissociation Fingerprints and Artificial Neural Networks

利用酯化/解离指纹图谱和人工神经网络快速电化学分析粪便短链脂肪酸

阅读:1

Abstract

Short-chain fatty acids (SCFAs) are key biomarkers of gut microbiota activity; however, routine quantification in fecal samples relies largely on chromatography, which is instrument-intensive and throughput-limited chromatography techniques. Herein, we present a rapid machine-learning-assisted electroanalysis platform for SCFAs profiling that integrates a disposable three-electrode planar gold chip with voltammetric fingerprinting and artificial neural network (ANN)-based signal decoupling. To generate orthogonal chemical information and improve the discrimination of structurally similar species, a dual pretreatment strategy combining acid-catalyzed esterification and alkaline dissociation was employed prior to electrochemical analyses. Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were employed to acquire high-dimensional fingerprints, from which current-, potential-, and area-based descriptors were extracted using a cross-information feature strategy. A hierarchical modeling framework improved total SCFAs prediction by incorporating ANN-predicted propionate and butyrate concentrations as auxiliary inputs. While linear calibration was achievable in standard mixtures, direct linear models performed poorly in real fecal matrices due to strong sample-dependent matrix interference. In contrast, the ANN captured nonlinear relationships among multifeature inputs and suppressed matrix effects. Validation against gas chromatography-mass spectrometry in an independent fecal test cohort (n = 30) demonstrated excellent agreement and low prediction errors, with mean absolute error/root mean square error values of 0.063/0.072 mM (propionic acid), 0.029/0.034 mM (butyric acid), and 0.135/0.202 mM (total SCFAs). The DPV/CV acquisition requires only minutes per sample, whereas pretreatment takes 1~3 h depending on the target route but can be performed in parallel for batch processing; thus, overall throughput is determined mainly by batch pretreatment rather than per-sample instrument time. This electrochemical-ANN workflow provides a portable, high-throughput alternative to chromatography for fecal SCFAs profiling in clinical screening and microbiome research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。