Accuracy-dependent dose-constraints and dose-based safety margins for organs-at-risk in radiotherapy

放射治疗中危及器官的精度依赖性剂量限制和基于剂量的安全裕度

阅读:2

Abstract

BACKGROUND AND PURPOSE: Geometrical uncertainties in radiotherapy are generally accounted for by margins for tumors, but their effect on organs-at-risk (OARs) is often ignored. We developed a model that incorporates dose- and geometry-based uncertainties in OAR planning using dose constraints. MATERIALS AND METHODS: Radiotherapy uncertainties cause real dose-volume histograms (DVHs) to spread around the planned DVH. With a published OAR dose constraint D(V(crit)) < D(crit) such that complication probability < Y%, real differences from planned D(crit) can be described by mean- (MD(Dcrit)) and standard deviations (SD(Dcrit)). Assuming complications are associated with the worst DVHs, New dose constraints that maintain complication probability can be derived for new treatments: D(crit,New) = D(crit,publ) + Φ(-1)(1 - Y%) * (SD(Dcrit,publ) - SD(Dcrit,New)) + (MD(Dcrit,publ) - MD(Dcrit,New)), with Φ(-1)(x) the inverse cumulative normal distribution function. Setting SD(Dcrit,New) = MD(Dcrit,New) = 0 in the recipe yields the "True" critical dose, and D(crit,True) - D(crit,publ) can be considered a dose-based safety margin (DSM).As hypothetical example, we estimated MD(Dcrit) and SD(Dcrit) values by simulating geometric errors in our clinical treatment plans and adding dose-based uncertainty. Over 1000 OARs with 108 different regular- and hypo-fractionation constraints were simulated. We assumed accuracy SDs to change from 2.5mm/3% to 1.5mm/2%. RESULTS: Results varied per OAR, fractionation, and constraint-type. If our 2.5mm/3% MD(Dcrit) and SD(Dcrit) values approximated dose-constraint studies, on average the DSM would be 4.5 Gy (18%) and our dose constraints would increase with 1.2 Gy (5%). CONCLUSIONS: We introduced a first model relating dose constraints and complication probabilities with treatment uncertainties and safety margins for OARs. Among other things, it quantified how higher constraints can be applied with increasing radiotherapy accuracy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。