Revisiting two thousand hinge fractures in open wedge high tibial osteotomy with a fifty years review: the oscillating saw cannot replace the traditional "ear-hand" dialogue between osteotome and hammer to estimate the elastic modulus of bone

对两千例开放楔形高位胫骨截骨术中的铰链骨折进行五十年回顾:摆动锯无法取代骨凿和骨锤之间传统的“耳语式”操作,以评估骨骼的弹性模量。

阅读:1

Abstract

BACKGROUND: Hinge fracture on the lateral part of the tibia (LHF) is a common complication of medial Open Wedge High Tibial Osteotomy (OWHTO). Many factors have been described as risks for these fractures, but no study has compared an osteotome or an oscillating saw to prevent LHF following OWHTO. METHODS: This "propensity-score-matched" (PSM) study was conducted from data obtained in the literature from 1974 to November 2024. A total of 10,368 knees with OWHTO were identified. After 1:1 matching based on correction amount, posterior slope change, surgeon's experience, the osteotome and oscillating groups comprised 2760 knees each. RESULTS: Among the 5520 knees of the PSM population, the prevalence of LHF was 6.1% in the osteotome alone group (168 cases), and 22% in the oscillating saw group (607 cases). The osteotome group had a significant lower prevalence of hinge fracture than the oscillating saw group (OR, 0.23; 95% CI, 0.19 to 0.27; p < 0.0001) and a lower rate of clinically relevant hinge fractures with revision (OR, 0.34; 95% CI, 0.25 to 0.45; p < 0.001. DISCUSSION: The osteotome may be an appropriate method for preventing hinge fractures following OWHTO.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。