Synthetic Contrast-Free LGE via Diffusion-Based Framework in Acute MI for Image Quality and Quantitative Scar Analysis

基于扩散框架的合成无对比剂LGE在急性心肌梗死图像质量和定量瘢痕分析中的应用

阅读:1

Abstract

BACKGROUND: This study aims to develop a diffusion model-based framework for generating late gadolinium enhancement (LGE)-like images without contrast. The resulting synthetic images are then comprehensively evaluated for subjective and objective image quality, as well as their clinical utility for quantifying scar in acute myocardial infarction. METHODS: In this retrospective study, we developed a diffusion mode-based framework, multisequence guided diffusion to generate synthetic native enhancement (SNE) images from cine magnetic resonance imaging, and T2 short tau inversion recovery sequences. Data were collected from 331 patients with acute myocardial infarction across 3 centers from January 2014 to July 2024. Subjective and objective image qualities were assessed using Likert scoring and contrast ratio analyses on both internal and external cohorts, comparing SNE with standard LGE to evaluate group differences. Myocardial contours were manually delineated, and scar size and transmurality were quantified using the full-width at half-maximum method to assess the accuracy of myocardial infarction detection. RESULTS: In comparisons with general generative models and multimodal fusion-based generative approaches, multisequence guided diffusion demonstrated more favorable visual perceptual quality and the closest data distribution alignment to conventional LGE. SNE demonstrated significantly higher quality than LGE (internal: 4.250 [4.000-4.750] versus 4.000 [3.750-4.500]; external: 4.250 [4.000-4.750] versus 4.000 [3.500-4.250]; P<0.05) and improved contrast ratios (blood pool versus myocardium: 9.010 [6.938-12.761] versus 8.767 [6.361-11.745] internally and 16.871 [12.546-24.237] versus 13.472 [9.380-19.599] externally; P<0.05). SNE showed strong agreement with LGE for scar size (internal R=0.839; external R=0.816; P<0.001) and transmurality (internal R=0.792; external R=0.758; P<0.001) with minimal biases (scar size: 2.490% internal, 2.222% external; transmurality: 2.984% internal, 2.225% external), indicating accurate scar depiction and robust generalizability. CONCLUSIONS: SNE demonstrated strong agreement with LGE in quantitative assessment of acute myocardial infarction scar, with comparable or improved image quality.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。