Disturbance observer based multiloop proportional feedback system for output voltage regulation in three phase AC to DC converters

基于扰动观测器的多环比例反馈系统用于三相交流-直流变换器的输出电压调节

阅读:2

Abstract

This paper suggests a disturbance observer (DOB)-based offset-free output voltage regulator for the three-phase AC/DC power converters, taking the nonlinearity, parameter, and load uncertainties into account. The proposed multiloop controller is designed in such a way that it feeds back only proportional errors and stabilizes the output voltage and current tracking errors involving the feed-forward compensation terms driven by the DOBs. The DOBs assist the inner and outer loop controllers to ensure the performance recovery and steady-state error rejection properties, which correspond to a major contribution of this article. A three-phase 3-kW AC/DC power converter is used for experimentally verifying the efficacy of the proposed technique.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。