Flexural Strength and Stress Analysis of CAD-CAM Milled Glass Fiber Post and Core

CAD/CAM铣削玻璃纤维桩核的弯曲强度和应力分析

阅读:1

Abstract

Intraradicular posts have the potential to induce mechanical stresses within the root structure during masticatory activities, hence contributing to fatigue and ultimately resulting in the fracture of the remaining dental structure. The objective of this work was to compare the stress pattern generated on the root by a computer-aided design and computer-aided manufacturing (CAD-CAM) milled fiberglass post under occlusal load in a photoelastic simulation and to compare its flexural strength (FS) to other types of posts. A total of 15 simulated roots, produced from photoelastic resins, were created using human canine teeth. These specimens were then separated into three distinct groups: Fiber post conventional, which consisted of fiberglass posts; fiber post customizable, which involved prefabricated fiberglass posts anatomized with composite resin; and fiber post CAD-CAM, which utilized CAD-CAM milled fiberglass posts. Following the application of Relyx ARC cement, the posts underwent photoelastic testing using a polariscope and FS testing using a universal testing machine. The data were submitted to analysis of variance (ANOVA) and Tukey's test at 5% significance level. It was found that the stress was significantly greater (p < 0.05) for the customizable post (246.5 MPa ± 218.7) in comparison to both the conventional (135.8 MPa ± 99.3) and CAD-CAM (136.5 MPa ± 68.4) posts; the latter group exhibited the lowest flexural values (50.8 MPa ± 7.9), which were significantly different from both the conventional group (123.0 MPa ± 26.9) and the customized group (230.3 MPa ± 18.9), which also differed from each other. The modulus of elasticity showed statistical differences (p  < 0.05) among the three different methods: CAD-CAM (0.50 GPa ± 0.06), conventional (1.75 GPa ± 0.13), and custom (3.46 GPa ± 0.19). The FS and elasticity modulus of customized posts were significantly higher than those of CAD-CAM, that exhibited the lowest values. Intermediate values were demonstrated by conventional posts. In comparison, to the customized post, the stress study revealed that conventional and CAD-CAM posts had a lower stress in the apical area and a lower general root stress value; but the cervical stress from CAD-CAM posts were practically twice of conventional and customized posts.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。