Structural resilience of skylights with perforated panels in healthcare facilities: a case study

医疗设施中穿孔板天窗的结构韧性:案例研究

阅读:1

Abstract

This study investigates the structural resilience of skylights integrated with perforated aluminum panels (Mashrabiya) in healthcare facilities under arid climate conditions. This study is based on a real, constructed skylight system installed in a healthcare facility, offering a rare field-based assessment rather than a purely theoretical or simulated model. The motivation behind this work stems from the need for energy-efficient, structurally robust, and aesthetically appealing skylight systems capable of withstanding extreme wind loads. Unlike conventional skylight studies, this research introduces a comprehensive numerical modelling approach in SAP2000 that incorporates nonlinear geometric effects, second-order buckling analysis, and stress concentration factors for perforated panels. The study evaluates deflections, stresses, and demand-to-capacity ratios (DCRs) under a wind load of 1.2 kPa, in accordance with local Standards. A key novelty of this study is the integration of perforated panels as both aesthetic and functional elements, enhancing structural performance by dissipating wind-induced stresses. The results indicate that the maximum DCR is 0.46, ensuring a significant safety margin, while the perforated panels exhibit a maximum stress of 41.05 MPa, well below the allowable limit of 160 MPa. Additionally, a mesh sensitivity analysis was conducted to optimise computational accuracy while balancing efficiency. The perforated aluminium panels (Mashrabiya) serve a dual function, enhancing aesthetics and acting as structural elements to redistribute and dissipate wind-induced stresses, a novel approach in skylight system design. This research advances wind-resistant façade design in arid climates by offering practical recommendations for optimising skylight configurations. Future work should focus on experimental validation through wind testing, real-time load monitoring, and parametric studies to support further structural optimisation. Unlike prior parametric or purely analytical works, this paper is based on a field‑installed skylight structure, using full‑scale geometry and validated against site‑measured boundary conditions. The study bridges the gap between experimental contexts and numerical modelling, thereby offering both practical and methodological novelty.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。