Numerical Cincinnati Stroke Scale Versus Stroke Severity Screening Tools for the Prehospital Determination of Large Vessel Occlusion

数字辛辛那提卒中量表与卒中严重程度筛查工具在院前确定大血管闭塞方面的比较

阅读:1

Abstract

OBJECTIVES: Previous research demonstrated that the numerical Cincinnati Prehospital Stroke Scale (CPSS) identifies large vessel occlusion (LVO) at similar rates compared to dedicated LVO screening tools. We aimed to compare numerical CPSS to additional stroke scales using a national emergency medical services (EMS) database. METHODS: Using the ESO Data Collaborative, the largest EMS database with linked hospital data, we retrospectively analyzed prehospital patient records from 2022. Each EMS record was linked to corresponding emergency department (ED) and inpatient records through a data exchange platform. Prehospital CPSS was compared to the Cincinnati Stroke Triage Assessment Tool (C-STAT), the Field Assessment Stroke Triage for Emergency Destination (FAST-ED), and the Balance Eyes Face Arm Speech Time (BE-FAST). The optimal prediction cut points for LVO screening were determined by intersecting the sensitivity and specificity curves for each scale. To compare the discriminative abilities of each scale among those diagnosed with LVO, we used the area under the receiver operating curve (AUROC). RESULTS: We identified 17,442 prehospital records from 754 EMS agencies with ≥1 documented stroke scale of interest: 30.3% (n = 5,278) had a hospital diagnosis of stroke, of which 71.6% (n = 3,781) were ischemic; of those, 21.6% (n = 817) were diagnosed with LVO. CPSS score ≥2 was found to be predictive of LVO with 76.9% sensitivity, 68.0% specificity, and AUROC 0.787 (95%CI 0.722-0.801). All other tools had similar predictive abilities, with sensitivity/specificity/AUROC of: C-STAT 62.5%/76.5%/0.727 (0.555-0.899); FAST-ED 61.4%/76.1%/0.780 (0.725-0.836); BE-FAST 70.4%/67.1%/0.739 (0.697-0.788). CONCLUSIONS: The less complex CPSS exhibited comparable performance to three frequently employed LVO detection tools. The EMS leadership, medical directors, and stroke system directors should weigh the complexity of stroke severity instruments and the challenges of ensuring consistent and accurate use when choosing which tool to implement. The straightforward and widely adopted CPSS may improve compliance while maintaining accuracy in LVO detection.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。