The potential of high-Z contrast media for vessel visualization near metal implants: a photon-counting detector CT phantom study with virtual monoenergetic images and iterative metal artifact reduction

高Z对比剂在金属植入物附近血管显像中的应用潜力:基于光子计数探测器CT体模、虚拟单能图像和迭代金属伪影校正的研究

阅读:1

Abstract

BACKGROUND: Metal artifacts in computed tomography (CT) can be reduced with high energy virtual monoenergetic images (VMI) and iterative metal artifact reduction (IMAR) algorithms. At high VMI energies, however, iodinated contrast media show decreased attenuation. High atomic number (high-Z) contrast media potentially preserve vessel contrast near metal implants even at high VMI energies. Hence, the purpose of this study was to assess the effect of high-Z contrast media on vessel visualization near metal implants in photon-counting detector (PCD)-CT across VMI energies, with and without IMAR and for different metal types. METHODS: A pelvis phantom containing titanium or steel inserts and contrast media inserts including iodine, bismuth, holmium, or tungsten was scanned using photon-counting detector computed tomography (PCD-CT). VMI (40-190 keV, 1 keV steps) were reconstructed with and without IMAR. Three predefined regions of interest (ROI) were placed in the background (background noise, standard deviation of HU), in the contrast media inserts (vessel attenuation, mean HU), and between the metal and contrast inserts (metal artifacts, defined as standard deviation of HU). An artifact-adjusted contrast-to-noise ratio (CNR) was calculated using background noise, vessel attenuation and metal artifacts, and averaged across three VMI energy ranges: 40-90, 90-140, and 140-190 keV. Peak CNR was the maximum value across all VMI energies. Wilcoxon rank sum tests with Benjamini-Hochberg correction were applied. RESULTS: Metal artifacts decreased with increasing VMI energy (P<0.001). Titanium caused fewer artifacts than steel, and IMAR further reduced artifacts from both metal types: at 40-90 keV without IMAR, metal artifacts averaged over all contrast media were 71 Hounsfield units (HU) (titanium) vs. 116 HU (steel), decreasing to 27 and 32 HU with IMAR (P<0.001). At 40-90 keV in titanium with IMAR, holmium showed the highest vessel attenuation and CNR (451 HU/24), followed by iodine (296 HU/15), bismuth (267 HU/14) and tungsten (259 HU/13). At 140-190 keV, tungsten showed the highest vessel attenuation and CNR (269 HU/19), followed by bismuth (250 HU/17), holmium (144 HU/10) and iodine (31 HU/2). Peak CNR [34] was achieved with holmium, titanium, IMAR, and VMI at 40 keV. CONCLUSIONS: High-Z contrast media provide superior vessel contrast compared to iodine near metal implants in PCD-CT, both at low VMI energy with holmium and at high VMI energy with tungsten and bismuth, where metal artifacts are additionally reduced. Under metal artifact conditions, vessel contrast can be further improved by applying IMAR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。