Reliability of Hand-Held Dynamometer in Measuring Gluteal Muscle Rate of Torque Development and Peak Torque: Push and Pull Configurations

手持式测力计测量臀肌扭矩发展速率和峰值扭矩的可靠性:推拉配置

阅读:1

Abstract

BACKGROUND: Belt-stabilized handheld dynamometers (HHD) assess hip rate of torque development (RTD) and strength in research and clinical practice. However, the reliability of HHD with push and pull configurations to measure hip muscles RTD and peak torque is unclear. PURPOSE/HYPOTHESIS: To determine the intra- and inter-reliability of HHD utilizing push and pull configurations to measure hip abduction and extension early (0-100ms) and late (100-200ms) phases RTD and peak torque. We hypothesized HHD with both configurations would be reliable for measuring hip extension and abduction RTD and peak torque. STUDY DESIGN: Cross-sectional study. METHODS: Twenty healthy adults (10 females) performed three consecutive maximal isometric contraction trials of hip abduction and extension, utilizing an HHD with push and pull configurations by two raters. Each rater's average early and late phases RTD and peak torque of hip abduction and extension were utilized for analysis. RESULTS: Intra-rater reliability of hip abduction with push and pull configurations ranged moderate-to-good for early and late RTD phases (push: ICC2,1=0.61-0.88; pull: ICC2,1=0.59-0.75). Peak hip abduction torque showed good reliability in both configurations (ICC2,1≥0.79). Hip extension ranged moderate-to-good reliability for early and late RTD phases in push configuration (ICC2,1=0.72-0.87), with good-to-excellent reliability in pull (ICC2,1=0.77-0.91). Peak hip extension torque showed moderate-to-excellent reliability for push configuration (ICC2,1=0.73-0.92) and excellent reliability for pull (ICC2,1≥0.91). Inter-rater reliability for hip abduction showed moderate in push (ICC3,k≥0.72) and good in pull (ICC3,k≥0.78) configurations for both RTD phases, while hip extension showed good reliability in push (ICC3,k≥0.82) and excellent reliability in pull (ICC3,k≥0.95) configurations. Peak torque showed good reliability for hip abduction (ICC3,k≥0.83) and excellent reliability for extension (ICC3,k≥0.94) in both configurations. CONCLUSIONS: HHD with push and pull configurations is a reliable and cost-effective method for assessing RTD and strength of hip abductors and extensors in healthy adults. LEVEL OF EVIDENCE: Level 3.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。