Impact of contralateral pelvic drop and femoral adduction on the femoral head acetabular coverage: A study on the reproducibility of a new radiographic measurement method

对侧骨盆下沉和股骨内收对股骨头髋臼覆盖率的影响:一项关于新型放射学测量方法可重复性的研究

阅读:2

Abstract

PURPOSE: Traditional radiographic measurements for acetabular dysplasia and femoroacetabular impingement syndrome (FAIS) are typically done in static positions, overlooking dynamic behaviours. This study investigated the reproducibility of a new radiographic method that incorporates pelvic and femoral motion during running. METHODS: This cross-sectional retrospective study included 10 patients (5 males/5 females; Mean 42.4, SD: 3.0 years) with symptomatic unilateral FAIS. Participants underwent three-dimensional running analysis and standard supine anteroposterior (AP) pelvis radiographs. Using specialised software, the femur and pelvis were rotated in the coronal plane according to peak angles of contralateral pelvic drop and femoral adduction from the running analysis, preserving the original hip joint centre. Two experienced physicians measured the lateral centre edge angle (LCEA), acetabular index (AI), sharp angle (SA), extrusion index (EI), and femoro-epiphyseal acetabular roof index (FEAR INDEX) on both standard and manipulated (M) radiographs in two rounds, with a 15-day interval. Differences between the original and manipulated measurements (VAR) were also calculated. Intra- and inter-rater reliability were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman method, with a significance level of 5%. RESULTS: The average contralateral pelvic drop and femoral adduction used for image manipulation were 4.7° (SD: 2.7) and 6.2° (SD: 2.4), respectively. Of the 15 radiographic measurements, 14 showed good to excellent inter-rater reliability in the first assessment (range: 0.76-0.98), which decreased to 11 in the second assessment (range: 0.80-0.96). Intra-rater reliability showed 13 and 12 measurements with good or excellent reliability for raters 1 (range: 0.75-0.97) and 2 (range: 0.79-0.97), respectively. CONCLUSION: This study demonstrates that incorporating dynamic motion into femoral head acetabular coverage radiographic measurements provides potential reliable assessments for most parameters. Integrating motion analysis with radiography could improve understanding of acetabular coverage in active individuals and support surgical decision-making. LEVEL OF EVIDENCE: Diagnostic Study, Level III.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。