Between-Day Reliability of Kinematic Variables Using Markerless Motion Capture for Single-Leg Squat and Single-Leg Landing Tasks

利用无标记运动捕捉技术评估单腿深蹲和单腿落地动作的运动学变量的日间可靠性

阅读:1

Abstract

BACKGROUND: Markerless motion capture has the potential to repeatedly collect biomechanical data during activities associated with injuries. Few studies have assessed the reliability of this technology during single-leg tasks. PURPOSE: The primary aim was to examine the between-day reliability of trunk and lower limb kinematics during single-leg squat and single-leg landing tasks using markerless motion capture. The secondary aim was to examine the between-day reliability of the same protocol using marker-based motion capture. DESIGN: Reliability. METHODS: Nineteen recreational athletes performed all tasks in two sessions, one week apart. Joint angles of trunk, hip, knee, and ankle were processed using Theia3D. A separate study (10 different participants) evaluated the reliability of marker-based motion capture. In both technologies, full curve analysis was examined using root mean square difference (RMSD) and discrete point analysis (initial contact and peak knee flexion) using intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Statistical parametric mapping (SPM) was also used for full curve analysis in markerless motion capture. RESULTS: For full curve analysis, markerless motion capture demonstrated low mean RMSD for all joints and planes in both SLS (3.6˚±1.3˚) and landing tasks (forward=3.2˚±1.3˚; medial=3.4˚±1.7˚). SPM showed statistical difference for bilateral hip flexion (full curve) and unilateral hip adduction, rotation, and knee flexion during a percentage of landing tasks. For discrete point analysis, ICC mean indicated moderate to good reliability (SLS= 0.77; forward landing= 0.83; medial landing= 0.80) with low mean SEM values (SLS=3.1°±1.3˚; forward landing=2.3˚±0.9°; medial landing=2.3˚±0.8˚). Marker-based motion capture showed slightly higher mean RMSD (SLS=4.2˚±1.8˚; forward landing=3.5˚±1.0˚; medial landing=3.3˚±0.9) and SEM values (SLS=4.1˚±2.2˚; forward landing=2.7˚±1.2°; medial landing=2.8˚±1.2˚). ICC mean showed good relative reliability (SLS=0.90; forward landing=0.88; medial landing=0.88). Hip flexion presented values >5° across tasks and technologies (RMSD and SEM= 5° to 8°). CONCLUSIONS: Markerless motion capture using Theia3D can reliably measure single-leg tasks with measurement errors comparable to marker-based motion capture. The low measurement error provides confidence for the regular monitoring of athletes during single-leg tasks. LEVEL OF EVIDENCE: 3.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。