Mesoscopic whole-brain T(2)*-weighted and associated quantitative MRI in healthy humans at 10.5 T

在10.5T磁场下对健康人进行中观全脑T(2)*加权及相关定量磁共振成像

阅读:1

Abstract

PURPOSE: To demonstrate the feasibility and performance of mesoscopic whole brain T(2)*-weighted (T(2)*w) MRI at 10.5 T by combining a motion-robust multi-echo gradient-echo (GRE) method with high-density RF receive arrays. METHODS: Multi-echo GRE data were collected in healthy adults at isotropic 0.5 mm resolution using a custom-built 16-channel transmit/80-channel receive (16Tx/80Rx) RF coil. Whole brain images were reconstructed with navigator-guided joint motion and field correction and were used for quantitative R (2)* and susceptibility (χ) mapping. Intrinsic signal-to-noise ratio (iSNR) and quantification precision for R (2)* and χ were also estimated. The results were compared with those obtained in the same subjects with matched resolution at 7 T using the commercial Nova 1Tx/32Rx coil, to demonstrate the iSNR and quantification precision gains at 10.5 T. G-factors were also calculated at each field strength to evaluate parallel imaging performances. To demonstrate the benefit of increased parallel imaging performances at 10.5 T, whole brain images with higher acceleration were also obtained using a custom-built 16Tx/128Rx coil. RESULTS: the utilized motion robust GRE sequence and reconstruction effectively reduced artifacts from motion and field changes during scans, producing high-quality whole-brain T(2)*w images and multi-parametric maps at 10.5 T with delineation of fine-scale brain structures. Compared to 7 T, the 10.5 T approach led to gains in both iSNR and quantification precision of R (2)* and χ. Quantitatively, iSNR estimated in the peripheral cortical gray matter increased by 42%. Parallel imaging performances were also improved at 10.5 T owing to the utilized high-density coils compared to the commonly used commercially available coil at 7 T, allowing high-quality images with up to 12-fold combined acceleration when using the 128Rx coil. CONCLUSION: It is feasible to perform motion-robust whole-brain mesoscopic multi-echo gradient echo imaging of the human brain at 10.5 T. Intrinsic SNR and quantification precision of R (2)* and χ were estimated and compared with 7 T results. The results presented here may shed light on future optimal implementation of anatomic T(2)*w brain MRI at ultrahigh field beyond 7 T.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。