Biomechanical Evaluation of a Novel V-Shaped A2 Pulley Reconstruction Technique Using a Free Palmaris Longus Tendon Graft Tenodesis

采用游离掌长肌腱移植固定术重建新型V形A2滑车的生物力学评价

阅读:1

Abstract

Background: The aim of this biomechanical investigation was to evaluate a V-shaped three-point graft tenodesis technique using a free palmaris longus (PL) tendon for reconstructing traumatic A2 pulley lesions and to compare its biomechanical performance with two previously described reconstruction techniques. Methods: After A2 pulley lesion simulation in 27 fingers (index, middle and ring finger) from nine human anatomical hand specimens, reconstructions were performed using the innovative V-shaped graft tenodesis technique, a double-loop encircling technique and a suture anchor graft fixation technique. Load at failure and the failure mechanisms were evaluated. Results: The V-shaped graft tenodesis technique was superior biomechanically (p = 0.004) considering load at failure (mean: 299 N). The only observed failure mechanism in this group was the extrusion of the central tenodesis screw. In contrast, reconstructions in the other two groups failed due to suture cut-out. Conclusions: Patients may benefit from the new technique's high load tolerance during early mobilization. Furthermore, a reduction in complications may be anticipated due to an absence of sutures and the sparing of extensor structures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。