Exome sequencing shows same pattern of clonal tumor mutational burden, intratumor heterogenicity and clonal neoantigen between autologous tumor and Vigil product

外显子组测序显示,自体肿瘤和Vigil产品之间克隆性肿瘤突变负荷、肿瘤内异质性和克隆性新抗原的模式相同。

阅读:1

Abstract

Retrospective data support overall survival (OS) advantage to high clonal tumor mutation burden (cTMB), high clonal neoantigen load (cNEO) and low intratumor heterogeneity (ITH) in cancer patients who receive immunotherapy. In order to explore this relationship prospectively with Vigil, a triple function targeted immunotherapy involving ovarian cancer patients in long term follow up of the Phase 2b VITAL trial, we developed an exome sequencing procedure and associated bioinformatics pipeline to determine clonal signal patterns. DNA libraries containing exome sequences tagged with unique molecular identifiers (UMI) were prepared from paired samples and sequenced on Illumina sequencers to high coverage depths of ~ 930X (tumor) and ~ 130X (normal). Raw sequence reads were processed into optimized binary alignment map (BAM) files, using the UMI information. The BAM files were inputted into modules for calling MHC-I alleles, annotating single nucleotide variants (SNVs) and small insertions/deletions (InDels), and for determination of allelic copy number. The outputs were used to predict the sequence of peptide neoantigens and to perform clonality analysis in order to assign each SNV and InDel in a patient tumor sample to a primary clone or subclone. The Clonal Neoantigen pipeline was further assessed using whole exome Illumina sequencing data from three previously published studies. Evaluation of the pipeline using synthetic sequencing data from a sub-clonal deconvolution tool benchmarking study, showed positive predictive value (PPV) and positive percent agreement (PPA) of > 97.5% and > 96.5%, respectively, for SNV and InDel detection with minimum requirements for variant density and allele fraction. Haplotype calls from the Clonal Neoantigen pipeline MHC-I/ MHC-II typing module matched a published benchmark for 91.5% of the calls in a sample of 99 patients. Analysis of exome sequencing data from 14 patients with advanced melanoma revealed a strong correlation between cTMB values determined by the Clonal Neoantigen pipeline as compared to those calculated from the published data (R(2) = 0.99). Following validation, the wet lab process and Clonal Neoantigen pipeline was applied to a set of matched normal, tumor, and Vigil product samples from 9 (n = 27 samples) ovarian cancer subjects entered into the VITAL (CL-PTL-119) trial. Results demonstrated marked correlation (R(2) = 0.98) of cTMB between tumor used to construct Vigil and Vigil product. Correlation between tumor and Vigil for the cNEO and ITH metrics, showed R(2) values of 0.95 and 0.87, respectively. The consistency of the Clonal Neoantigen pipeline results with previously published data as well as the agreement between results for tumor and Vigil for the entire system provide a strong basis of support for utilization of this pipeline for prospective determination of cTMB, cNEO, and ITH values in clinical tumor tissue in order to explore possible correlative relationships with clinical response parameters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。