Reliability of Ultrasound Based Compressibility of the Lower Leg Anterior Tibial Muscle Compartment in Healthy Volunteers

健康志愿者小腿前胫肌隔室超声可压缩性测量的可靠性

阅读:1

Abstract

BACKGROUND: Some individuals have exercise-induced lower leg pain (ELP) caused by a chronic exertional compartment syndrome (CECS). As intracompartmental muscle pressure measurements are invasive with suboptimal test characteristics, other diagnostic tools are needed. Recently, ultrasound-based muscle compartment thickness analysis at 10mmHg (d10) and 80mmHg (d80) external pressure was introduced for this purpose. The difference in compartment thickness at these two external pressures induced by the study device is used to calculate muscle compressibility, a possible marker for CECS. PURPOSE: The purpose of this study was to investigate the reliability of a novel ultrasound compressibility technique using two distinct internal landmarks at the lower leg in a diverse group of asymptomatic adults. STUDY DESIGN: Cross-sectional study. METHODS: Healthy volunteers (n=35; 21 female; median age 40 years, range 19-72; BMI 24.1 kg/m2, range 18.3-31.6) not having ELP underwent serial compressibility measurements (n=1678) of both legs by three observers at the tibialis anterior (TA) using the interosseous membrane (IM) and transition zone IM to tibial bone (TZIT) as internal landmarks. Inter- and intra-observer reliability was calculated for values of d10, d80 and compressibility using intraclass correlations (ICC). RESULTS: TA compartments are less compressible using the IM landmark compared to the TZIT landmark (10.5% vs 12.5%; p<0.001). Inter-observer ICC for IM was always higher (d10 0.85; d80 0.82; compressibility 0.51) than for TZIT (d10 0.65; d80 0.53; compressibility 0.20). The intra-observer reliability for d10 and d80 was excellent (ICC>0.90) for all three observers. ICC of compressibility varied among observers and ranged from 0.76 to 0.48, with higher ICCs demonstrated for IM compared to TZIT. CONCLUSION: Ultrasound based anterior tibial muscle compressibility measurements have moderate inter-observer reliability and excellent intra-observer reliability if the interosseous membrane is used as internal landmark. Future studies are aimed to test muscle compressibility after exercise and in CECS. LEVEL OF EVIDENCE: Level 3.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。