Evaluating the efficacy, safety, and predictors of failure following cardiac resynchronization therapy in a developing country: an ambispective, multi-center study

评估发展中国家心脏再同步治疗的疗效、安全性和失败预测因素:一项前瞻性、多中心研究

阅读:1

Abstract

BACKGROUND: Multiple studies have demonstrated that cardiac resynchronization therapy (CRT) effectively improves the prognosis of heart failure. CRT has been proven to improve patients' quality of life and reduce the risk of readmission and death in selected patients. Nevertheless, a notable proportion of individuals undergoing CRT showed no response. Therefore, we conducted this study to describe CRT characteristics and reported the outcomes 1 year after discharge in Vietnam, along with predictors of non-response to CRT. METHODS: This was a multicenter, ambispective cohort study that enrolled all CRT implantation patients at five hospitals in Ho Chi Minh City: University Medical Center Ho Chi Minh City, Heart Institute of Ho Chi Minh City, Tam Duc Heart Hospital, Thong Nhat Hospital, and Vinmec Central Park Hospital. All patients received treatment according to established guidelines and were monitored for up to 1 year after being discharged. Primary outcomes included rehospitalization and mortality rate 1 year after discharge. Secondary outcomes included early and late complications related to the procedure. RESULTS: Between April 2016 and April 2020, 88 cases of successful CRT implantation from five hospitals were enrolled. The majority of the population was male (68.2%), mean age was 62.5±13.4 years old, New York Heart Association (NYHA) III/IV at admission (98.9%), and the mean left ventricular ejection fraction (LVEF) was 24%±5.9%. The incidence of early complications was 9.1%. The overall mortality rate was 12.5%, with 6.8% occurring within the 1-year follow-up period. The population experienced a significant decrease in readmission rate within 1 year after discharge (P=0.001). Additionally, there was a notable improvement in the NYHA function (P<0.001) and an enhancement in the quality of life (P=0.001). Five characteristics correlated with the lack of response to CRT were history of dobutamine usage, QRS interval (QRS) length before implantation, severe ventricular arrhythmias before implantation, atrial fibrillation after implantation, and severe ventricular arrhythmias after implantation. CONCLUSIONS: Properly used CRT device improves heart failure symptoms, mortality, and readmissions. There are several predictors of cardiac resynchronization treatment failure. This information helps us comprehend the restricted patient group and develop better treatments, especially in low-income countries.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。