Remote EEG Acquisition in Angelman Syndrome using PANDABox-EEG

使用 PANDABox-EEG 对安格曼综合征患者进行远程脑电图采集

阅读:1

Abstract

Objective: We describe the development and validation of PANDABox-EEG, a novel protocol for remote EEG assessment with no on-site technician, tailored for Angelman syndrome (AS). We argue that this protocol is reliable, valid, and widely acceptable for use in families affected by Angelman syndrome. Background: AS is a rare neurogenetic condition characterized by developmental delays, sleep problems, seizures, and a happy demeanor. People with AS are frequently monitored via EEG to inform clinical care, and EEG-measured delta activity has been proposed as a reliable biomarker to monitor treatment effectiveness. Traditional EEG assessments pose logistical and financial burdens for families due to the need to travel to a medical center to complete assessments. Telehealth methods, however, offer a pathway forward. Methods: PANDABox-EEG was developed through multidisciplinary collaboration with psychologists, psychophysiologists, engineers, and special-education scholars, incorporating caregiver feedback and user-centered design principles. It pairs PANDABox, a telehealth platform for biobehavioral assessment in rare disorders, with ANT Neuro dry electrode EEG system. Twenty-eight participants (7 AS, 7 siblings, 14 caregivers) completed three 5-minute EEG sessions each over the course of a week. Caregivers were asked to provide feedback on acceptability of the design, and EEG data was quantified and assessed for metrics of reliability and validity. Results: PANDABox-EEG demonstrated high feasibility and acceptability, with 91% of caregivers reporting strong satisfaction assessment comfort. EEG data quality was promising, with high internal consistency (split-half reliability range for children with AS: r= .96-.98) and test-retest reliability for delta power among (test-retest reliability range for children with AS: ρ = .88-.96). Finally, we successfully detected the characteristic increased delta power in AS (effect size between AS and non-AS siblings: d=1.56-2.85) and its association with age (effect size between non-AS siblings and caregivers: d=2.19-2.72). Conclusion: PANDABox-EEG provides a feasible, cost-effective, and reliable method for remote EEG assessment in AS. Its high caregiver satisfaction and ability to capture relevant neurophysiological markers suggest potential for broader application. With further validation, PANDABox-EEG can enhance accessibility and inclusivity, benefiting clinical management and research in AS and other clinical populations in need of frequent EEG monitoring by eliminating the need to travel.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。