Quantification of Metamorphopsia Using a Smartphone-Based Hyperacuity Test in Patients With Idiopathic Epiretinal Membranes: Prospective Observational Study

利用智能手机超视力测试量化特发性视网膜前膜患者的视物变形:前瞻性观察研究

阅读:1

Abstract

BACKGROUND: Quality of vision in patients with idiopathic epiretinal membranes (iERMs) is closely linked to distorted vision (metamorphopsia), which is often underestimated in clinical settings. Current surgical decision-making relies heavily on visual acuity and optical coherence tomography findings, which do not adequately reflect the patient's functional vision or the severity of metamorphopsia. There is a clinical need for tools that can reliably quantify this symptom to improve patient outcomes and streamline care pathways. OBJECTIVES: This study is the first to assess the use of a novel smartphone-based hyperacuity test (SHT) in quantifying metamorphopsia before and after surgical intervention for iERMs, comparing it with a conventional printed chart. METHODS: This prospective observational study included 27 patients with iERMs with symptomatic metamorphopsia detected on the Amsler grid scheduled for vitrectomy with membrane peeling. The SHT (Alleye, Oculocare Medical Inc) and the horizontal (MH) and vertical (MV) M-chart (Inami & Co, Ltd) tests were performed 3 times before and 3 months after surgery. Pre- and postoperative metamorphopsia scores, changes in distance-corrected visual acuity, optical coherence tomography biomarkers, and subjective perception of metamorphopsia were evaluated. RESULTS: The mean SHT score significantly (r=0.686; P<.001) improved from 55.2 (SD 18.9) before surgery to 63.5 (SD 16.3) after surgery while the improvement of the M-chart scores were insignificant (MH r=0.37, P=.06; MV r=0.18, P=.36). Pre- and postoperative SHT scores showed very weak and insignificant correlations with the MH, MV, and MH+MV scores. Both metamorphopsia tests showed good reliability (intraclass correlation coefficients >0.75). CONCLUSIONS: The SHT showed a significant improvement in postoperative metamorphopsia scores, indicating that it could be a valuable tool for quantifying visual distortion in patients with iERMs. While discrepancies with M-chart results were observed, both tests demonstrated good reliability. Clinically, the SHT may offer a practical solution for monitoring metamorphopsia and guiding complex surgical decision-making, particularly in telemedicine settings. Its accessibility could improve patient management, potentially enhancing preoperative triaging and reducing unnecessary visits.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。