Total wrist arthroplasty revisited: survival, function, and patient-reported outcomes of BIAX and universal II prostheses over 15 years

全腕关节置换术再探:BIAX 和 Universal II 型假体 15 年生存率、功能和患者报告结果

阅读:1

Abstract

BACKGROUND: In the management of degenerative osteoarthritis and rheumatoid arthritis of the wrist, surgical intervention remains an important treatment option when conservative approaches such as medication, physiotherapy, and assistive devices prove insufficient. Despite decades of development, no single wrist prosthesis has yet emerged as the definitive standard in total wrist arthroplasty. To address this gap, the German Society for Hand Surgery established the Total Endoprosthesis (TEP) Register in 2004 to systematically collect and evaluate long-term clinical outcomes. The present prospective single-centre study analyses and presents the long-term results of patients enrolled in the TEP register, offering valuable insights into the performance and durability of wrist prostheses in a real-world clinical setting. PATIENTS/MATERIALS/METHODS: Between 2000 and 2011, a total of 29 total endoprostheses were implanted in 25 patients in a single centre study due to severe degenerative changes in the wrist. Of these, 22 had rheumatoid arthritis and 3 degenerative osteoarthritis. The prosthesis models BIAX (N = 13) and Universal II (N = 16) were implanted. The present study describes the mean outcome after a mean observation period of 13.8 (1.7-21.4) years for the BIAX prosthesis and 10.5 years (0.2-16.4) for the Universal II prosthesis. RESULTS: The probability of survival after 15 years is 60% for the BIAX prosthesis and 41% for the Universal II prosthesis. After 21 years, results are only available for the BIAX prosthesis with a value of 60%. The BIAX prosthesis showed a lower complication rate. Subjectively, 15 years postoperatively, the BIAX prosthesis showed a lower mean value in the QuickDASH score (BIAX 33.8%, Universal II 50.3%), lower results in the visual analogue pain scale under stress (BIAX: 1 point; Universal II: 3 points) with higher patient satisfaction (BIAX: 86%; Universal II: 78%). CONCLUSION: In conclusion, our observations show that the BIAX prosthesis is superior to the Universal II prosthesis 15 years after surgery in terms of survival probability, complication rate and better results in satisfaction, the visual analogue pain scale and the QuickDASH score.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。