The ALT-SPF ring study - in vitro determination of the SPF & UVA-PF by the fused method

ALT-SPF环状研究——采用熔融法体外测定SPF和UVA-PF

阅读:1

Abstract

OBJECTIVE: In the framework of the Alt-SPF consortium, a large ring study was conducted to evaluate different alternative methods for SPF determination. This paper reports and discusses the results of a new in vitro approach, the Fused Method. The study aimed to determine whether the Fused Method would provide similar SPF results to those obtained using ISO 24444 and whether UVA-PF would be comparable to ISO 24443. METHODS: The Fused Method is based on assessing UV transmittance through a film of sunscreen applied to PMMA plates, before and after 1MED irradiation through the film. An individual calibration curve is measured by each operator using standard sunscreens to correct for individual/equipment error throughout the process. This calibration is formulation-dependent: there is one calibration for emulsion, one for single-phase formulations, and one for mineral UV filters. RESULTS: Optimization of the calibration step to an asymptotic regression model improved inter-laboratory reproducibility and showed lower method bias compared to ISO 24444. Most PGs met the full statistical validation criterion for SPF results. The results of PG1 (low viscosity emulsion SPF30), PG2 (medium viscosity emulsion SPF6) and PG4 (medium viscosity emulsion SPF30) indicate a product and product group-specific method bias. This observation was confirmed for PG1 in the follow-up study. The same conclusion could be drawn for the evaluation of UVA-PF versus ISO 24443, as this parameter is directly linked to the SPF results. CONCLUSION: The use of the Fused Method to determine the SPF of sunscreen formulations meets the statistical criteria for most PGs. However, intra-laboratory reproducibility needs to be improved for low SPF values and low viscosity emulsions. Nevertheless, this fast, simple, and cost-effective method remains a good alternative for SPF & UVA-PF screening in the development of sunscreen formulations. It is a pragmatic approach to manage the various known biases (applicator/device) of in vitro transmittance SPF measurement. No significant change to ISO 24443 is required, and the method allows in vitro SPF & UVA-PF to be determined in the same setup.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。