ANATOMICAL STUDY OF VOLAR FACE OF DISTAL RADIUS AND COMPARISON WITH THE SHAPE OF LOCKING VOLAR PLATES

桡骨远端掌面的解剖研究及与锁定掌骨板形状的比较

阅读:9
作者:Luciana Cascão Lima, Antonio Carlos DA Costa, Pedro Sire Salgado, Ana Claudia Fernandez Onoue

Conclusion

Radial bone anatomy was variable. The intermediate column was, on average, steeper than lateral column. Synthes®-2 plate presented the closest design to the anatomy of the distal end of the radial bone, followed by Newclip®-2 plate. Level of Evidence II, Anatomic and Descriptive Study. Objetivos: Avaliar o ângulo palmar cortical (APC) da extremidade distal do rádio, sua variação nas colunas lateral e intermédia, o formato e o padrão da watershed line (WL) e sua correlação com as placas volares bloqueadas disponíveis no mercado. Métodos: Foram analisados 27 ossos rádios do Departamento de Morfologia e nove placas de seis fabricantes diferentes. Medimos os APCs das colunas lateral e intermédia dos rádios e seus correspondentes nas placas, além de compararmos o relevo do terço distal do rádio e das placas. Quanto a WL, comparamos o formato nas peças e seu equivalente nas placas, sendo classificados em quatro tipos: biconvexo, convexo, convexo ulnar e plano. Resultados: O APC variou entre as colunas do rádio, sendo a média da coluna lateral 153,40° e, da intermédia 146,06°. Quatro das nove placas não apresentaram variação na angulação volar. Dos 27 rádios, 13 apresentaram padrão convexo e 12 biconvexo, enquanto a maioria das placas (sete das nove analisadas) tinham desenho biconvexo. Conclusão: A anatomia dos rádios foi variável entre as peças, sendo a coluna intermédia mais inclinada que a coluna lateral. A placa Synthes ® -2 foi a que apresentou relevo mais próximo dos achados anatômicos da extremidade distal do rádio, seguida pela Newclip ® -2. Nível de Evidência II, Estudo Anatômico Descritivo.

Methods

27 human cadaveric radial bones of the Department of Morphology and nine locking volar plates of six different companies were analyzed. VCA were measured from lateral and intermediate columns and their corresponding values on plates, as well as comparing the relief of radius and plates. In the WL analysis, we compared the standard format found on the radius and its equivalent on plates and divided into four types: biconvex, convex, ulnar convex and plan.

Objective

To evaluate the volar cortical angle (VCA), the variation in lateral and intermediate columns, the shape and pattern of the watershed line (WL) of the distal radius and its correlation with locking volar plates available.

Results

VCA varied between columns of the distal radius extremity. The mean in the lateral column was 153.40 degrees and 146.06 degrees in the intermediate. Four of nine plates showed no variation in volar angulation. From 27 distal radius, 13 showed convex pattern and 12 had biconvex, whereas most plates (seven of the nine analyzed) were biconvex drawing.