Grid and Image Intensifier Improve Arthroscopic ACL Tunnel Position and Patient-Reported Outcomes

网格和图像增强器可改善关节镜下前交叉韧带隧道定位和患者报告结果

阅读:1

Abstract

PURPOSE: To evaluate the accuracy in the femoral and tibial tunnel placement after the use of fluoroscopy along with an indigenously designed grid method to assist in arthroscopic anterior cruciate ligament reconstruction as compared with the tunnel placement without using them and to validate the findings with computed tomography scan performed postoperatively along with assessing the functional outcome at a minimum of 3 years of follow-up. METHODS: This was a prospective study conducted on patients who underwent primary anterior cruciate ligament reconstruction. Patients were included and segregated into a nonfluoroscopy (group B) and a fluoroscopy group (group A), and both had postoperative computed tomography scans so that femoral and tibial tunnel position could be evaluated. Scheduled follow-up occurred 3, 6, 12, 24, and 36 months' postoperatively. Patients were evaluated objectively with the Lachman test, measurement of range of motion, and functional outcome using patient-reported outcome measures, i.e., Tegner Lysholm Knee score, Knee injury and Osteoarthritis Outcome Score, and International Knee Documentation Committee subjective knee score. RESULTS: A total of 113 subjects were included. There were 53 in group A and 60 in group B. The average location of femoral tunnel showed significant differences between the 2 groups. However, the variability in femoral tunnel location was significantly lower in group A as compared with group B for proximal-distal planes only. The average location of the tibial tunnel as per the grid of Bernard et al. showed significant differences in both the planes. The variability in tibial tunnel was greater in the medial-lateral plane as compared with the anterior-posterior plane. There was a statistically significant difference in mean value of the 3 scores among the 2 groups. The variability of the scores was greater in group B as compared with group A. None of the patient was reported as a failure. CONCLUSIONS: The results of our study suggests that fluoroscopy-guided positioning using a grid technique increases the accuracy of anterior cruciate ligament tunnel positioning with decreased variability and is associated with better patient-reported outcomes 3 years after surgery compared with tunnel positioning using landmarks. LEVEL OF EVIDENCE: Level II, prospective, comparative therapeutic trial.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。