Digitally Based Blood Pressure Self-Monitoring Program That Promotes Hypertension Self-Management and Health Education Among Patients With Low-Income: Usability Study

一项旨在促进低收入患者高血压自我管理和健康教育的数字化血压自我监测计划:可用性研究

阅读:1

Abstract

BACKGROUND: According to evidence-based clinical guidelines, adults with hypertension are advised to self-monitor their blood pressure (BP) twice daily. Self-measured BP monitoring is a recommended strategy for improving hypertension management. OBJECTIVE: We aimed to determine the feasibility and acceptability of a digitally based BP self-monitoring program that promotes hypertension self-management and health education among low-income patients. We hypothesized that the program would be highly feasible and acceptable and that at least 50% of the patients would use the monitor at the rate required for the reimbursement of the device's cost (16 days of measurements in any 30-day period). METHODS: Withings BPM Connect was deployed to patients at Family Health Centers of San Diego. Program elements included training, SMS text message reminders, and physician communication. Compliance, use, mean BP, and BP control status were calculated. A Kaplan-Meier time-to-event analysis was conducted to compare time to compliance between a strict definition (≥16 days in any rolling 30-day window) and a lenient definition (≥1 day per week for 4 consecutive weeks). A log-rank test was performed to determine whether the difference in time to compliance between the definitions was statistically significant. Mean systolic BP (SBP) and diastolic BP (DBP) before the intervention and after the intervention and mean change in SBP and DBP across patients were calculated. Paired sample t tests (2-tailed) were performed to assess the changes in SBP and DBP from before to after the intervention. RESULTS: A total of 179 patients received the monitors. The mean changes in SBP and DBP from before to after the intervention were +2.62 (SE 1.26) mm Hg and +3.31 (SE 0.71) mm Hg, respectively. There was a statistically significant increase in both SBP and DBP after the intervention compared with before the intervention (P=.04 and P<.001). At the first and last measurements, 37.5% (63/168) and 48.8% (82/168) of the patients had controlled BP, respectively. During the observation period, 83.3% (140/168) of the patients had at least 1 controlled BP measurement. Use decreased over time, with 53.6% (90/168) of the patients using their monitor at week 2 and only 25% (42/168) at week 11. Although only 25.6% (43/168) achieved the strict definition of compliance, 42.3% (71/168) achieved the lenient definition of compliance. The median time to compliance was 130 days for the strict definition and 95 days for the lenient definition. The log-rank test showed a statistically significant difference in time to compliance between the compliance definitions (P<.001). Only 26.8% (45/168) complied with the measurement rate that would result in device cost reimbursement. CONCLUSIONS: Few patients used the monitors at a rate that would result in reimbursement, raising financial feasibility concerns. Plans for sustaining costs among low-income patients need to be further evaluated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。