Digital Holographic Microscopy in Veterinary Medicine-A Feasibility Study to Analyze Label-Free Leukocytes in Blood and Milk of Dairy Cows

数字全息显微镜在兽医学中的应用——分析奶牛血液和牛奶中无标记白细胞的可行性研究

阅读:1

Abstract

For several years, the determination of a differential cell count of a raw milk sample has been proposed as a more accurate tool for monitoring the udder health of dairy cows compared with using the absolute somatic cell count. However, the required sample preparation and staining process can be labor- and cost-intensive. Therefore, the aim of our study was to demonstrate the feasibility of analyzing unlabeled blood and milk leukocytes from dairy cows by means of digital holographic microscopy (DHM). For this, we trained three different machine learning methods, i.e., k-Nearest Neighbor, Random Forests, and Support Vector Machine, on sorted leukocyte populations (granulocytes, lymphocytes, and monocytes/macrophages) isolated from blood and milk samples of three dairy cows by using fluorescence-activated cell sorting. Afterward, those classifiers were applied to differentiate unlabeled blood and milk samples analyzed by DHM. A total of 70 blood and 70 milk samples were used. Those samples were collected from five clinically healthy cows at 14-time points within a study period of 26 days. The outcome was compared with the results of the same samples analyzed by flow cytometry and (in the case of blood samples) also to routine analysis in an external laboratory. Moreover, a standard vaccination was used as an immune stimulus during the study to check for changes in cell morphology or cell counts. When applied to isolated leukocytes, Random Forests performed best, with a specificity of 0.93 for blood and 0.84 for milk cells and a sensitivity of 0.90 and 0.81, respectively. Although the results of the three analytical methods differed, it could be demonstrated that a DHM analysis is applicable for blood and milk leukocyte samples with high reliability. Compared with the flow cytometric results, Random Forests showed an MAE of 0.11 (SD = 0.04), an RMSE of 0.13 (SD = 0.14), and an MRE of 1.00 (SD = 1.11) for all blood leukocyte counts and an MAE of 0.20 (SD = 0.11), an RMSE of 0.21 (SD = 0.11) and an MRE of 1.95 (SD = 2.17) for all milk cell populations. Further studies with larger sample sizes and varying immune cell compositions are required to establish method-specific reference ranges.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。