Blood-brain barrier permeability measured using dynamic contrast-enhanced magnetic resonance imaging: a validation study

利用动态对比增强磁共振成像测量血脑屏障通透性:一项验证性研究

阅读:1

Abstract

KEY POINTS: The blood-brain barrier (BBB) is an important and dynamic structure which contributes to homeostasis in the central nervous system. BBB permeability changes occur in health and disease but measurement of BBB permeability in humans is not straightforward. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to model the movement of gadolinium contrast into the brain, expressed as the influx constant K(i) . Here evidence is provided that K(i) as measured by DCE-MRI behaves as expected for a marker of overall BBB leakage. These results support the use of DCE-MRI for in vivo studies of human BBB permeability in health and disease. ABSTRACT: Blood-brain barrier (BBB) leakage can be measured using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as the influx constant K(i) . To validate this method we compared measured K(i) with biological expectations, namely (1) higher K(i) in healthy individual grey matter (GM) versus white matter (WM), (2) GM/WM cerebral blood volume (CBV) ratio close to the histologically established GM/WM vascular density ratio, (3) higher K(i) in visibly enhancing multiple sclerosis (MS) lesions versus MS normal appearing white matter (NAWM), and (4) higher K(i) in MS NAWM versus healthy individual NAWM. We recruited 13 healthy individuals and 12 patients with MS and performed whole-brain 3D DCE-MRI at 3 T. K(i) and CBV were calculated using Patlak modelling for manual regions of interest (ROI) and segmented tissue masks. K(i) was higher in control GM versus WM (P = 0.001). CBV was higher in GM versus WM (P = 0.005, mean ratio 1.9). K(i) was higher in visibly enhancing MS lesions versus MS NAWM (P = 0.002), and in MS NAWM versus controls (P = 0.014). Bland-Altman analysis showed no significant difference between ROI and segmentation methods (P = 0.638) and an intra-class correlation coefficient showed moderate single measure consistency (0.610). K(i) behaves as expected for a compound marker of permeability and surface area. The GM/WM CBV ratio measured by this technique is in agreement with the literature. This adds evidence to the validity of K(i) measured by DCE-MRI as a marker of overall BBB leakage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。