Integrating Point-of-Care Bacterial Fluorescence Imaging-Guided Care with Continued Wound Measurement for Enhanced Wound Area Reduction Monitoring

将床旁细菌荧光成像引导护理与持续伤口测量相结合,以增强伤口面积缩小监测。

阅读:1

Abstract

AIM: This prospective observational study investigated wound area reduction (WAR) outcomes in a complex wound population composed of non-healing acute and chronic wounds. The relationship between bacterial autofluorescence signals and WAR was investigated. Area measurements were collected both manually and digitally, and both methods were compared for accuracy. METHODS: Twenty-six participants with 27 wounds of varying etiologies were observed twice weekly for two weeks. Digital wound measurement, wound bacterial status assessment, and targeted debridement were performed through a point-of-care fluorescence imaging device (MolecuLight(®) i: X, MolecuLight Inc, Toronto, Canada). The wound area reduction (WAR) rate was calculated using baseline and last visit measurements. Statistical analyses, including t-tests, Fisher exact tests, the Wilcoxon signed rank test for method comparison, and ANOVA for bacterial subgroups, were applied as pertinent. RESULTS: The overall average WAR was -3.80 cm(2), or a decrease of 46.88% (manual measurement), and -2.62 cm(2), or a 46.05% decrease (digital measurement via MolecuLight(®) device). There were no statistically significant differences between the WAR of acute and chronic wounds (p = 0.7877). A stepwise correlation between the WAR and bacterial status classification per fluorescence findings was observed, where persistent bacteria resulted in worse WAR outcomes. An overestimation of wound area by manual measurement was 23% on average. CONCLUSION: Fluorescence imaging signals were linked to WAR outcome and could be considered predictive. Wounds exhibiting bacterial loads that persisted at the end of the study period had worse WAR outcomes, while those for which management was able to effectively remove them demonstrated greater WAR. Manual measurement of the wound area consistently overestimated wound size when compared to digital measurement. However, if performed by the same operator, the overestimation was uniform enough that the WAR was calculated to be close to accurate. Notwithstanding, single wound measurements are likely to result in overestimation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。