Factors influencing mechanical failure following intramedullary nailing of proximal femur fractures: a retrospective cohort study

影响股骨近端骨折髓内钉固定术后机械失效的因素:一项回顾性队列研究

阅读:1

Abstract

BACKGROUND: Proximal femur fractures are a common injury in elderly patients and are associated with high morbidity and mortality worldwide. Recent data indicate that the age-standardized incidence of hip fractures in adults over 55 years has increased significantly. We aimed to identify radiographic stability parameters and patient- or procedure-related factors associated with clinical fixation success following intramedullary nailing of proximal femur fractures. METHODS: In this retrospective study, we evaluated 373 patients aged ≥35 years who underwent proximal femoral nail (PFN) implantation for intertrochanteric, pertrochanteric, subtrochanteric, or reverse-oblique femur fractures at our tertiary center between 2012 and 2024. Fractures were classified preoperatively using the Evans classification system, and the quality of reduction was graded as good, fair, or poor according to the standard radiographic Modified Baumgaertner criteria. Radiographic variables, including proximal lag screw tip-head distance (ApLAG1), distal lag screw tip-head distance (ApLAG2), ApLAG2-calcar distance, lesser trochanter-calcar distance, lateral lag screw tip-apex distance (LatTAD), and normal-side lesser trochanter-calcar distance, were measured postoperatively. Clinical outcomes were categorized into two groups: success or failure. RESULTS: The cohort (mean age: 78.06±12.79 years; 66.5% female) included 262 (70.2%) standard PFNs, 79 (21.2%) integrated intertrochanteric antegrade nails (InterTAN) PFNs, and 32 (8.6%) single-screw PFNs. Overall, 359 patients (96.2%) had successful fixation and 14 (3.8%) experienced failure. No significant differences were found in radiographic parameters between the success and failure groups. PFN type did not influence radiographic measurements except for ApLAG2-related variables, in which InterTAN and single-screw nails differed from standard PFNs (p<0.001). Univariate analysis revealed that only poor reduction quality was significantly associated with failure (χ²=36.298; p<0.001). CONCLUSION: Quality of fracture reduction emerged as the sole independent predictor of PFN fixation success, whereas patient demographics, Evans classification, and implant design did not significantly affect outcomes. Surgeons should prioritize achieving nearanatomic alignment and stable implant positioning to minimize mechanical failure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。