Evaluating Disposable Isolation Gown Liquid Barrier Test Methods for Relevance to Healthcare

评估一次性隔离衣液体阻隔性测试方法在医疗保健领域的相关性

阅读:2

Abstract

Healthcare staff rely on isolation gowns to provide a degree of protection against cross contamination from blood or body fluids. Gowns that meet standardized liquid barrier penetration test methods provide staff with a presumed assurance of safety. However, these test methods-namely impact penetration and resistance to hydrostatic pressure-were not drafted with personal protective equipment in mind and therefore may be inappropriate for testing products intended for use in a healthcare environment. This study found that adjusting testing parameters to better simulate clinical conditions altered the measured performance outcomes of the gowns. Specifically, increasing the temperature of the gown material's preconditioning environment or test liquid resulted in statistically significant variations in results. Further, although hydrostatic pressure resistance is measured by the appearance of a third liquid droplet on the inner surface of the gown material, the first two droplets appeared at significantly lower pressures and likely would constitute contamination of healthcare staff. The results indicated that current isolation gown test protocols and regulations should be reevaluated to more accurately reflect healthcare scenarios and improve alignment with expected barrier performance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。