Ablative Five-Fraction CT Versus MR-Guided Stereotactic Body Radiation Therapy for Pancreatic Cancer: In Silico Evaluation of Interfraction Anatomic Changes as a Rationale for Online Adaptive Replanning

胰腺癌消融性五次CT引导立体定向放射治疗与MR引导立体定向放射治疗的比较:基于计算机模拟的分次间解剖结构变化评估,为在线自适应重计划提供理论依据

阅读:1

Abstract

Background/Objectives: Non-ablative stereotactic body radiation therapy (SBRT) is commonly employed for locally advanced pancreatic cancer (LAPC) using computed tomography-guided radiotherapy (CTgRT) without online adaptive radiation therapy (oART). The safe delivery of ablative SBRT has been demonstrated using stereotactic magnetic resonance-guided online adaptive radiation therapy (SMART). We performed an in silico comparison of non-adapted CTgRT versus SMART to better understand the potential benefit of oART for ablative pancreatic SBRT. Methods: We retrospectively evaluated original and daily adapted SMART plans that were previously delivered for 20 consecutive LAPC cases (120 total plans across all patients) treated on a 0.35 T MR-linac prescribed to 50 Gy (gross disease) and 33 Gy (elective sites) simultaneously in five fractions. Six comparative CTgRT plans for each patient (one original, five daily treatment) were retrospectively generated with the same prescribed dose and planning parameters as the SMART plans assuming no oART availability. The impact of daily anatomic changes on CTgRT and SMART plans without oART was evaluated across each treatment day MRI scan acquired for SMART. Results: Ninety percent of cases involved the pancreatic head. No statistically significant differences were seen between CTgRT and SMART with respect to target coverage. Nearly all (96%) fractions planned on either CT or MRI platforms exceeded at least one GI organ at risk (OAR) constraint without oART. Significant differences favoring SMART over non-adaptive CTgRT were observed for the duodenum V35 Gy ≤ 0.5 cc (34.2 vs. 41.9 Gy, p = 0.0035) and duodenum V40 Gy ≤ 0.03 cc (37 vs. 52.5 Gy, p = 0.0006) constraints. Stomach V40 Gy trended towards significance favoring SMART (37 vs. 40.3 Gy, p = 0.057) while no significant differences were seen. Conclusions: This is the first study that quantifies the frequency and extent of GI OAR constraint violations that would occur during ablative five-fraction SBRT using SMART vs. CTgRT. GI OAR constraint violations are expected for most fractions without oART whereas all constraints can be achieved with oART. As such, these data suggest that oART should be required for ablative five-fraction pancreatic SBRT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。