Image Repeat Analysis in Conventional Radiography in Mobile Clinics: A Retrospective Observational Study

移动诊所常规放射摄影图像重复分析:一项回顾性观察研究

阅读:1

Abstract

BACKGROUND: Mobile clinics offer crucial healthcare services, including X-ray examinations, to underserved communities. Minimizing image repeats in this setting is vital due to radiation exposure, patient inconvenience, and cost implications. OBJECTIVES: This study investigated the prevalence and causes of image repeat in conventional radiography performed within mobile clinics in the Philippines. METHODS: A retrospective review analyzed data from five mobile clinics located in two highly urbanized cities in the Philippines from July to December 2023). Radiology staff assessed image quality, with suboptimal images requiring retakes. Reasons for rejection were categorized. RESULTS: Out of 871 radiographs taken, 118 (13.55%) were repeated. Vertebrae and pelvic girdle images had the highest repeat rates (33.33%). Positioning errors were the most common cause (44.07%), followed by underexposure and overexposure. CONCLUSION: This study identified a concerning repeat rate (13.55%) for mobile X-rays, primarily due to improper patient positioning, particularly for specific body parts. Targeted training programs and stricter protocols for mobile clinic staff are needed. Radiography education should also emphasize these skills, potentially through collaboration with mobile clinic operators to ensure graduates are prepared for the unique challenges of this environment.