Tibial morphological difference between metal augmentation and actual tibia for revision total knee arthroplasty

翻修全膝关节置换术中金属增强物与实际胫骨之间的胫骨形态差异

阅读:1

Abstract

BACKGROUND: An overhang of the tibial component can cause irritation of the surrounding soft tissues, whereas an underhang is associated with risks of tibial bone resorption. It is not well known whether the tapering angle of currently available blocks at medial, lateral, anterior, and posterior sides matches the actual shape of the proximal tibia. The purpose of this study was to analyze the bony contour of the proximal tibia and measure the tapering angle to examine whether the angle of currently available metal augmentation blocks matches the actual tibia. METHODS: Computed tomography of the lower extremities was performed on 100 consecutive knees, and three-dimensional images of the tibia were reconstructed. The primary resection level was determined on the basis of a plane 10 mm below the center of the lateral tibial plateau. The assumed levels were set to 5, 10, 15, and 20 mm below the primary resection level. All points that were 5, 10, 15, or 20 mm below were projected onto the primary resection surface, and the reduction value from the primary level to each level was measured. The tapering angle was calculated on the basis of the reduction value from the primary level to each resection surface at eight areas and compared with the angle of currently available metal augmentation acquired from the company. The distances of mismatch between the metal augmentation and the bone surface were calculated. RESULTS: The tapering angle on the medial and lateral sides increased with the more distal resection level, which was up to 30° at the 20 mm level. The tapering angle on the posterior side also increased with the more distal resection level, which was approximately 40° at the 20 mm level. The tapering angle of the current implant was smaller than that of the original tibial morphology. The distances of mismatch varied between implants in which the maximum distance was up to 11.3 mm in the 15 mm augmentation. CONCLUSIONS: The design of current metal augmentation differs from the morphology of the proximal tibia. Surgeons should pay attention to the size mismatch between the femoral and tibial components during revision total knee arthroplasty (TKA).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。