Adjacent segment degeneration after superior facet joint violation of the lumbar spine

腰椎上关节突关节损伤后邻近节段退变

阅读:2

Abstract

BACKGROUND: Facet joint violation (FJV) is a recognized complication of pedicle screw fixation and has been proposed as a driver of adjacent segment disease (ASD). Biomechanical models suggest that FJV may alter segmental kinematics, but its clinical impact on degeneration and reoperation remains uncertain. This work evaluates whether superior FJV is associated with an increased risk of radiographic ASD or reoperation after lumbar fusion. METHODS: Retrospective cohort study of patients undergoing lumbar pedicle screw fixation with postoperative CT imaging that captured the instrumentation and the cranial adjacent segment. Superior FJV was graded using an established 3-tier system. Follow-up imaging was assessed for disc height loss, progression of spondylolisthesis, coronal deformity, central stenosis, lateral recess height and a composite degeneration endpoint; reoperations were recorded. Propensity score weighting balanced measured covariates, and a weighted cox regression was used for time-to-event analyses. RESULTS: Seventy-one patients met inclusion criteria, with FJV identified in 35 (49.3%). Weighted analyses demonstrated no significant association between FJV and disc height loss (HR 1.21, 95% CI 0.54-2.72), progression of spondylolisthesis (HR 0.59, 95% CI 0.13-2.65), coronal deformity (HR 2.18, 95% CI 0.48-10.01), central stenosis (HR 1.35, 95% CI 0.21-8.61), composite degeneration (HR 1.76, 95% CI 0.87-3.56), or reoperation (HR 0.44, 95% CI 0.12-1.62). Exploratory subgroup analysis suggested that minor (grade 1) violations may contribute to axial instability, whereas full joint traversal (grade 2) may confer relative stability, though neither reached statistical significance. CONCLUSIONS: In this cohort with extended follow-up, superior FJV was not significantly associated with any measure of radiographic degeneration or reoperation. These findings suggest that FJV may not be a major determinant of long-term outcomes after lumbar fusion. Further biomechanical and clinical studies are warranted to clarify whether specific grades of FJV differentially affect cranial segment stability and screw performance. 140 CHARACTERS: Superior FJV on CT didn't significantly increase hazards of disc height loss, listhesis, stenosis, deformity, or reop after fusion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。