Diagnostic validity of flow cytometry vs manual counting of polymorphonuclear leukocytes in spontaneous bacterial peritonitis

流式细胞术与人工计数多形核白细胞在自发性细菌性腹膜炎诊断中的有效性比较

阅读:1

Abstract

BACKGROUND: Spontaneous bacterial peritonitis (SBP) is frequently occurring infection among patients with liver cirrhosis, defined by polymorphonuclear (PMN) leukocytic count ≥250 cell/mm(3) with or without a positive ascitic fluid (AF) bacterial culture. So, this study aimed to investigate the diagnostic value of flow cytometry versus manual counting of ascitic fluid PMNL in cirrhotic patients, with clinical suspicion of SBP. METHODS: A hospital-based cross-sectional study was carried out on 320 cirrhotic patients with clinical suspicion of SBP. Abdominal paracentesis was performed in all cases for microscopic manual and flow cytometry counting of PMNL. Anti-HLA-DR, anti-CD15, anti-CD16, and anti-CD45 monoclonal antibodies were used for flow cytometry method. RESULTS: Flow cytometric PMNL count had 100% sensitivity and specificity, while manual PMNL count had a sensitivity of 65.52% and specificity of 90% with significant difference (P value < .05). CONCLUSION: Flow cytometry is more reliable rapid method for PMNL counting, than the manual method that is less accurate and time-consuming in diagnosing clinically suspected SBP.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。