Association Between Obesity and Discordance in Fibrosis Stage Determination by Magnetic Resonance vs Transient Elastography in Patients With Nonalcoholic Liver Disease

非酒精性肝病患者中,肥胖与磁共振成像和瞬时弹性成像确定的纤维化分期不一致之间的关联

阅读:1

Abstract

BACKGROUND & AIMS: Magnetic resonance elastography (MRE) and transient elastography (TE) are noninvasive techniques used to detect liver fibrosis in nonalcoholic fatty liver disease. MRE detects fibrosis more accurately than TE, but MRE is more expensive, and the concordance between MRE and TE have not been optimally assessed in obese patients. It is important to determine under which conditions TE and MRE produce the same readings, so that some patients can simply undergo TE evaluation to detect fibrosis. We aimed to assess the association between body mass index (BMI) and discordancy between MRE and TE findings, using liver biopsy as the reference, and validated our findings in a separate cohort. METHODS: We performed a cross-sectional study of 119 adults with nonalcoholic fatty liver disease who underwent MRE, TE with M and XL probe, and liver biopsy analysis from October 2011 through January 2017 (training cohort). MRE and TE results were considered to be concordant if they found patients to have the same stage fibrosis as liver biopsy analysis. We validated our findings in 75 adults with nonalcoholic fatty liver disease who underwent contemporaneous MRE, TE, and liver biopsy at a separate institution from March 2010 through May 2013. The primary outcome was rate of discordance between MRE and TE in determining stage of fibrosis (stage 2-4 vs 0-1). Secondary outcomes were the rate of discordance between MRE and TE in determining dichotomized stage of fibrosis (1-4 vs 0, 3-4 vs 0-2, and 4 vs 0-3). RESULTS: In the training cohort, there was 43.7% discordance in findings from MRE versus TE. BMI associated significantly with discordance in findings from MRE versus TE (odds ratio, 1.69; 95% confidence interval, 1.15-2.51; P = .008) after multivariable adjustment by age and sex. The findings were confirmed in the validation cohort: there was 45.3% discordance in findings from MRE versus TE. BMI again associated significantly with discordance in findings from MRE versus TE (odds ratio, 1.52; 95% confidence interval, 1.04-2.21; P = .029) after multivariable adjustment by age and sex. CONCLUSIONS: We identified and validated BMI as a factor significantly associated with discordance of findings from MRE versus TE in assessment of fibrosis stage. The degree of discordancy increases with BMI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。