Effectiveness of the Attachment Design and Thickness of Clear Aligners during Orthodontic Anterior Retraction: Finite Element Analysis

正畸前牙内收过程中隐形矫治器附件设计及厚度的有效性:有限元分析

阅读:1

Abstract

OBJECTIVE: Clear aligner treatment (CAT) provides orthodontic patients with a comfortable treatment alternative; however, this device has limited capacity to facilitate tooth movements. Although composite attachment has been proposed to facilitate tooth displacement, some of its aspects, such as aligner thickness, can influence CAT's precision. This work aimed to compare the stress distribution patterns produced by clear aligners with different thicknesses and composite attachment shapes during anterior retraction. MATERIALS AND METHODS: Maxillary models consisting of clear aligners, maxillary teeth, and various attachments to the upper central incisor's labial surface were generated. Three models were built to mimic the retraction of the upper central incisors. Each had a distinct attachment design (rectangular attachment, ellipsoid attachment, and pyramidal attachment) and various aligner thicknesses (0.75, 0.85, 0.95, 1.05, and 1.15 mm). Upper central incisor retraction was accomplished using clear aligners. Finite element analysis was used to examine the built models. Stress distribution pattern was examined. RESULTS: The greater the thickness of the aligner, the higher the stress experienced by the teeth. The 0.75 mm-thick aligner induces the lightest stress with a minimum of 0.0037623 MPa and a maximum of 0.32859 MPa. Meanwhile, the 1.5 mm-thick aligner has the highest stress with a minimum of 0.004679 MPa and a maximum of 0.43858 MPa. The force distribution on rectangular attachments appears evenly distributed. The maximum pressure force on rectangular attachments has a minimum of 0.38828 MPa, which is smaller than the maximum on ellipsoid and pyramidal attachments at 0.40933 and 0.45099 MPa, respectively. CONCLUSION: The best aligner thickness is 0.75 to 0.85 mm for anterior retraction. An aligner with 0.95 mm thickness can still be used when a remarkable amount of tooth movement force is needed; however, this exception is only applicable to a limited number of clear aligner trays. The ellipsoid attachment is the best type of attachment because the resulting force is substantial and evenly distributed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。