Artificial Intelligence Applied to Chest X-ray: A Reliable Tool to Assess the Differential Diagnosis of Lung Pneumonia in the Emergency Department

人工智能在胸部X光片中的应用:急诊科评估肺部肺炎鉴别诊断的可靠工具

阅读:1

Abstract

BACKGROUND: Considering the large number of patients with pulmonary symptoms admitted to the emergency department daily, it is essential to diagnose them correctly. It is necessary to quickly solve the differential diagnosis between COVID-19 and typical bacterial pneumonia to address them with the best management possible. In this setting, an artificial intelligence (AI) system can help radiologists detect pneumonia more quickly. METHODS: We aimed to test the diagnostic performance of an AI system in detecting COVID-19 pneumonia and typical bacterial pneumonia in patients who underwent a chest X-ray (CXR) and were admitted to the emergency department. The final dataset was composed of three sub-datasets: the first included all patients positive for COVID-19 pneumonia (n = 1140, namely "COVID-19+"), the second one included all patients with typical bacterial pneumonia (n = 500, "pneumonia+"), and the third one was composed of healthy subjects (n = 1000). Two radiologists were blinded to demographic, clinical, and laboratory data. The developed AI system was used to evaluate all CXRs randomly and was asked to classify them into three classes. Cohen's κ was used for interrater reliability analysis. The AI system's diagnostic accuracy was evaluated using a confusion matrix, and 95%CIs were reported as appropriate. RESULTS: The interrater reliability analysis between the most experienced radiologist and the AI system reported an almost perfect agreement for COVID-19+ (κ = 0.822) and pneumonia+ (κ = 0.913). We found 96% sensitivity (95% CIs = 94.9-96.9) and 79.8% specificity (76.4-82.9) for the radiologist and 94.7% sensitivity (93.4-95.8) and 80.2% specificity (76.9-83.2) for the AI system in the detection of COVID-19+. Moreover, we found 97.9% sensitivity (98-99.3) and 88% specificity (83.5-91.7) for the radiologist and 97.5% sensitivity (96.5-98.3) and 83.9% specificity (79-87.9) for the AI system in the detection of pneumonia+ patients. Finally, the AI system reached an accuracy of 93.8%, with a misclassification rate of 6.2% and weighted-F1 of 93.8% in detecting COVID+, pneumonia+, and healthy subjects. CONCLUSIONS: The AI system demonstrated excellent diagnostic performance in identifying COVID-19 and typical bacterial pneumonia in CXRs acquired in the emergency setting.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。