Nine Years of Continuous Flow LVAD (HeartMate 3): Survival and LVAD-Related Complications before and after Hospital Discharge

九年连续流左心室辅助装置(HeartMate 3):出院前后生存率及左心室辅助装置相关并发症

阅读:1

Abstract

BACKGROUND: End-stage heart failure is associated with high mortality. Recent developments such as the left ventricular assist device (LVAD) have improved patient outcomes. The HeartMate 3 LVAD is a novel centrifugal pump that was developed to provide hemodynamic support in heart failure patients, either as a bridge-to-transplant (BTT), myocardial recovery, or destination therapy (DT). Our objective was to evaluate the survival rates and LVAD-related complications of the HeartMate 3 LVAD before and after hospital discharge in our center. METHODS: We retrospectively reviewed all patients implanted with the HeartMate 3 LVAD in our institute between September 2015 and June 2024. Patients who received a Heart Ware Ventricular Assist Device (HVAD) and HeartMate 2 LVAD devices were excluded. The primary endpoint was survival before and after hospital discharge. The secondary endpoints included an incidence of serious LVAD adverse events (bleeding, major infection, hemolysis, device thrombosis and malfunction, and neurological dysfunction) and the causes of re-admission along the follow-up period. RESULTS: A total of 48 consecutive HeartMate 3 LVAD patients were enrolled in this study. The mean age was 56.1 ± 10.6 years. A total of 72.9% of patients received LVAD therapy as a BTT, 14.6% as DT, 10.4% as a bridge-to-decision, and 2.1% as a bridge-to-recovery. A total of 85.4% of patients were discharged after implantation. The main cause for in-hospital mortality was right ventricular failure (8.3%), followed by stroke, abdominal bleeding, and multi-organ failure (2.1% each). One patient (2.1%) had successful heart transplantation, 26 patients (63.4%) are still on LVAD support, and 11 (26.8%) patients have died during follow-up. The main cause of mortality after hospital discharge was sepsis, which occurred in 9.8% of patients, followed by right ventricular failure, non-LVAD-related causes, unknown causes with two (4.9%) cases each, and one case of fatal stroke (2.4%). During the follow-up, there was no need for LVAD replacement. CONCLUSIONS: HeartMate 3 LVAD is associated with excellent in-hospital survival rates in patients with end-stage heart failure. Right ventricular failure was the main cause of death before hospital discharge, whereas sepsis was the main cause of death after hospital discharge.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。